MAN00000772_SI-G200BB_SVCPDFA - 第355页

Adjustment HLGB-10420-01 Area Sensor Optical Ax is Adjustment SHEET 3/3 Cassette specification is different from tray specification in jig hole to be used. Holes on the front are for cassette specification and holes on t…

100%1 / 712
Adjustment
HLGB-10420-01
Area Sensor Optical Axis Adjustment
SHEET
2/3
2 Turn ON power for the unit to check that the
floodlighting area sensors are installed on
the right side of the unit.
3 Set the optical axis adjustment jig to the
position of supply No. 101.
1. Check that the replacing carrier has
been raised.
2. Set the optical axis adjustment jig on
the cassette table of supply No.101.
There should be no gap between the optical axis
adjustment jig and the cassette table.
4 Adjust mounting position of the area sensor
so that optical axis of the area sensor
passes through center of the hole on the
optical axis adjustment jig.
The right figure describes how to adjust the area
sensor on the right side as an example. Also adjust
position of the area sensor on the left side in the same
way.
1. Loosen the mounting bolts for the area
sensor to adjust up and downward
positions.
2. Loosen the cap screw on the lower side
of the bracket to adjust forward and
backward position of the area sensor.
Rear
Front
Optical axis
adjustment jig
Area sensor
Optical axis
Adjustment
HLGB-10420-01
Area Sensor Optical Axis Adjustment
SHEET
3/3
Cassette specification is different from tray
specification in jig hole to be used.
Holes on the front are for cassette specification
and holes on the back are for tray specification
with the optical axis adjustment jig being placed
on the cassette table.
5 When putting optical axis adjustment jig on
the supply No. 101, 120 and 140, check that
the sensor is turned ON.
6 When shielding the area sensor by hand,
check that the sensor is turned OFF on the
I/O monitor screen.
1. Remove the optical axis adjustment
jig.
2. Click in an order of MANUAL menu
I/O tab Serial I/O button
Input tab.
Serial I/O screen is displayed.
3. When shielding the area sensor by
hand, check that the sensor is turned
OFF.
For tray specification
For cassette specification
Adjustment
HLGB-10421-01
Ejector Setup
SHEET
1/2
Ejector Setup
[Procedure]
1 Press the [ORG] button on the operation
panel to perform origin position return.
2 Adjust the pusher to the ORG sensor
position.
1. Set four holes on the left side pulley
horizontally/vertically.
2. Move the pusher by hand so that the
pusher left face is at the ORG position.
3. Loosen the screws on the mounting
bracket for the ORG sensor.
4. Tighten the screws on the mounting
bracket to fix on a boundary where the
LED on the ORG sensor changes to
lighting off to lighting up.
3 Move the pusher further in left direction, and
check that the LED on the CCW sensor
lights off before the pusher contacts the
mechanical end.
If the pusher contacts the mechanical end before the
LED on the CCW sensor lights off, adjust the position
of the ORG sensor.
Ejector belt
ORG sensor OT sensor
Pusher left face
ORG
position
Pusher Left side pulley