MAN00000772_SI-G200BB_SVCPDFA - 第356页
Adjustment HLGB-10421-01 Ejector Setup SHEET 1/2 Ejector Setup [Procedure] 1 Press the [ORG] button on the operation panel to perform origin position return. 2 Adjust the pusher to the ORG sensor position. 1. Set four ho…

Adjustment
HLGB-10420-01
Area Sensor Optical Axis Adjustment
SHEET
3/3
Cassette specification is different from tray
specification in jig hole to be used.
Holes on the front are for cassette specification
and holes on the back are for tray specification
with the optical axis adjustment jig being placed
on the cassette table.
5 When putting optical axis adjustment jig on
the supply No. 101, 120 and 140, check that
the sensor is turned ON.
6 When shielding the area sensor by hand,
check that the sensor is turned OFF on the
I/O monitor screen.
1. Remove the optical axis adjustment
jig.
2. Click in an order of MANUAL menu
I/O tab Serial I/O button
Input tab.
Serial I/O screen is displayed.
3. When shielding the area sensor by
hand, check that the sensor is turned
OFF.
For tray specification
For cassette specification

Adjustment
HLGB-10421-01
Ejector Setup
SHEET
1/2
Ejector Setup
[Procedure]
1 Press the [ORG] button on the operation
panel to perform origin position return.
2 Adjust the pusher to the ORG sensor
position.
1. Set four holes on the left side pulley
horizontally/vertically.
2. Move the pusher by hand so that the
pusher left face is at the ORG position.
3. Loosen the screws on the mounting
bracket for the ORG sensor.
4. Tighten the screws on the mounting
bracket to fix on a boundary where the
LED on the ORG sensor changes to
lighting off to lighting up.
3 Move the pusher further in left direction, and
check that the LED on the CCW sensor
lights off before the pusher contacts the
mechanical end.
If the pusher contacts the mechanical end before the
LED on the CCW sensor lights off, adjust the position
of the ORG sensor.
Ejector belt
ORG sensor OT sensor
Pusher left face
ORG
position
Pusher Left side pulley

Adjustment
HLGB-10421-01
Ejector Setup
SHEET
2/2
4 Adjust position of the CW sensor.
1. Move the pusher to the right side
mechanical end by hand.
2. Shift the pusher by approximately
1mm in left direction from the
mechanical end.
3. Loosen the screws on the mounting
bracket for the CE-CW sensor.
4. Fix the sensor mounting bracket on a
boundary where the LED on the
CE-CW sensor changes from lighting
off to lighting up.
CW sensor
Pusher