MAN00000772_SI-G200BB_SVCPDFA - 第367页

Adjustment HLGB-10425-01 Adjustment and checking of H-axis soft ware limit SHEET 2/6 3 T emporarily change value of H axis sof tware limit in the ac_param.ini file for the front side and rear side to value out side of th…

100%1 / 712
Adjustment
HLGB-10425-01
Adjustment and checking of H-axis
software limit
SHEET
1/6
Adjustment and checking of H-axis software limit
[Procedure]
1 Click in an order of SERVICE menu
Explorer button.
Explorer screen is displayed.
2 Put ac_param.ini file for front side and rear
side into a rewritable status.
1. For the front side, open Properties
window for ac_param.ini file in
C:¥asm¥mcdata1.
2. For the rear side, open Properties
window for ac_param.ini file in
C:¥asm¥mcdata2.
Right-click the file and select “Properties” from
the shortcut menu to open the Properties window.
3. Uncheck “Read-only” on the Properties
window of the ac_param.ini file.
4. Click the OK button.
Adjustment
HLGB-10425-01
Adjustment and checking of H-axis
software limit
SHEET
2/6
3 Temporarily change value of H axis software
limit in the ac_param.ini file for the front side
and rear side to value outside of the
over-travel.
1. Open Notepad by the ac_param.ini
file.
2. Input “3.800” into a space of
“SOFT_LIMIT_PLUS” of [AC_H].
3. Input “- 30.00” into a space of
“SOFT_LIMIT_MINUS” of [AC_H].
4. Save the ac_param.ini file and end.
5. Open the Properties window of the
ac_param.ini file, and check the
“Read-only”.
4 Re-start the unit.
1. Close the explorer window.
2. Press the power off switch.
Shutting down of the system starts and the power
is automatically shut off.
3. Press the power on switch.
The system starts, and the set value is reflected
on the equipment.
5 Check motion of the OT sensor at the top
end of the H-axis.
1. Click in an order of MANUAL menu
AXIS MOTION tab R.H button.
RN/H Axis screen is displayed.
Power on switch
Power off switch
3.800
-30.00
Adjustment
HLGB-10425-01
Adjustment and checking of H-axis
software limit
SHEET
3/6
2. Click the Abs. Move button.
3. Click the H-axis button and input “1.5”
into the input space.
4. Press the [START] button on the
operation panel.
The H-axis absolute-moves to a position of
1.5mm.
5. Click the Jog Move button in the move
mode.
6. Press the upward cursor to jog-move
the H-axis to a position of 1.6mm, and
check that alarm of over-travel is
displayed.
Unless the alarm of over-travel is displayed
when the H-axis is at the position of 1.6mm,
re-perform “Adjustment of OT sensor at top end
of H-axis [HLGB-10404-01]”.
7. Press the [ORG] button on the
operation panel.
Origin position return of the H axis is performed.
6 Check motion of the OT sensor at the
bottom end of the H-axis.
1. Click the Abs. Move button on the
RN/H-axis screen.
2. Click the H-axis button and input
“-26.5” into the input space.
3. Press the [START] button on the
operation panel.
The H-axis absolute-moves to a position of
-26.5mm.
-26.5