MAN00000772_SI-G200BB_SVCPDFA - 第612页

9 Functional Description

100%1 / 712
How to check RAS alarm
BBGB-10102-01
How to check RAS alarm
SHEET
4/4
[RAS Alarm list]
Alarm name Cause
Bit
display
Error
code on
HI
Recovery method
WDT alarm
VCPU failure, SDIO failure, ASM software does not
start up. Wiring for WDT is broken.
1111 F
Shut down by power off switch,turn
off main breaker, re-start up
Power ON error
PS_ON is not outputted from WCPU, and then ATX
power (PC power) is not turned ON.
0001 1
Check the cable, replace the WCPU
board
AC power error
ATX power detects AC power drop or power failure,
performs shutdown processing, turns OFF PC
power, and turns OFF machine control.
0010 2
Turn off main breaker, re-start up
after resetting AC power
DC voltage error 1
ATX power detects error of DC output voltage, PC
power is not turned ON, ATX power is failed
0011 3 Replace ATX power
DC voltage error 2
Vol tage of (ATX power5V output) dropped, ATX
power is failed
0100 4 Replace ATX power
Temperature rise
error 1
Measurement value of temperature sensor on RAS
board exceeded set value. Filter is clogged.
0101 5 Clean the filter
Temperature rise
error 2
Measurement value of temperature sensor installed
in enclosure exceeded set value, filter is clogged
0110 6 Clean the filter
Power fan stop Fan in ATX power stopped, ATX power is failed 0111 7 Replace the ATX power
WCPU fan stop
Cooling fan for WCPU stopped, fan is failed, wire
broken
1000 8 Replace the fan
VCPU fan stop
Cooling fan for VCPU stopped, fan is failed, wire
broken
1001 9 Replace the fan
Enclosure fan stop
Any fan among four enclosure fans stopped, fan is
failed, wire broken
1010 A Replace the fan
Battery boltage drop ATX power detects battery terminal voltage drop 1011 B Charge or replace the battery
* When the RAS board backed up, the equipment is in rest without issuing any alarm.