00198711-01_UM_X-Serie-S_EN.pdf - 第104页
3 Technical data and assemblies Instruction manual SIPLACE X-Series 3.1 Performance data From software version 713.0 Edition 11/2019 104 3.1.4 SIPLACE X3 S machine performance 3 Placement head type s SIPLACE SpeedStar (C…

Instruction manual SIPLACE X-Series 3 Technical data and assemblies
From software version 713.0 Edition 11/2019 3.1 Performance data
103
3.1.3 SIPLACE X4 S machine performance
3
Placement head types SIPLACE SpeedStar (C&P20 P)
SIPLACE SpeedStar (C&P20 P2)
SIPLACE MultiStar (CPP)
SIPLACE TwinStar (TH)
SIPLACE X4 S
Placement performance
For a definition of placement performance values, see the note on page 101.
Placement area 1 Placement area 2 IPC value Benchmark
value
X4 S-A C&P20 P / C&P20 P C&P20 P / C&P20 P 105,000 125,000
C&P20 P / C&P20 P CPP_L/CPP_L 90,500 106,500
C&P20 P / C&P20 P CPP_H / CPP_H 86,250 101,500
C&P20 P2 / C&P20 P2 C&P20 P/ C&P20 P2 130,000 150,000
C&P20 P2 / C&P20 P2 CPP_L/CPP_L 102,400 119,000
C&P20 P2 / C&P20 P2 CPP_H / CPP_H 98,500 114,000
CPP_L/CPP_L CPP_L/CPP_L 74,800 88,000
CPP_L/CPP_L CPP_H / CPP_H 70,900 83,000
CPP_H / CPP_H CPP_H / CPP_H 67,000 78,000
X4 S-B C&P20 P / C&P20 P CPP_H/TH 68,500 87,000
C&P20 P2 / C&P20 P2 CPP_H/TH 86,250 99,500
CPP_L/CPP_L CPP_H/TH 58,650 68,500
CPP_H / CPP_H CPP_H/TH 54,750 63,500
X4 S-C C&P20 P / C&P20 P TH / TH 60,500 71,500
C&P20 P2 / C&P20 P2 TH / TH 74,000 84,000
CPP_L/CPP_L TH / TH 46,400 53,000
CPP_H / CPP_H TH / TH 42,500 48,000
X4 S-D CPP_H/TH TH / TH 28,750 33,000
X4 S-E TH / TH TH / TH 16,000 18,000
CPP_H = SIPLACE Multistar CPP in high assembly position
CPP_L = SIPLACE Multistar CPP in low assembly position

3 Technical data and assemblies Instruction manual SIPLACE X-Series
3.1 Performance data From software version 713.0 Edition 11/2019
104
3.1.4 SIPLACE X3 S machine performance
3
Placement head types SIPLACE SpeedStar (C&P20 P)
SIPLACE SpeedStar (C&P20 P2)
SIPLACE MultiStar (CPP)
SIPLACE TwinStar (TH)
SIPLACE X3 S
Placement performance
For a definition of placement performance values, see the note on page 101.
Placement
machine
Placement area 1 Placement area 2 IPC value Benchmark
value
X3 S-A C&P20 P / C&P20 P C&P20 78,100 94,500
C&P20 P / C&P20 P CPP_L 73,200 84,500
C&P20 P / C&P20 P CPP_H 70,100 82,000
C&P20 P2 / C&P20 P2 C&P20 P 97,950 112,500
C&P20 P2 / C&P20 P2 CPP_L 83,700 97,000
C&P20 P2 / C&P20 P2 CPP_H 81,750 94,500
CPP_L/CPP_L CPP_L 57,375 67,500
CPP_H / CPP_H CPP_H 50,250 58,500
CPP_L/CPP_L CPP_H 54,150 63,500
X3 S-B C&P20 P / C&P20 P TH 57,000 67,500
C&P20 P2 / C&P20 P2 TH 69,500 80,000
CPP_L/CPP_L TH 41,900 49,000
CPP_H / CPP_H TH 38,000 44,000
X3 S-C CPP_H/TH TH 25,750 29,500
X3 S-D TH / TH TH 12,500 14,000
CPP_H = SIPLACE Multistar CPP in high assembly position
CPP_L = SIPLACE Multistar CPP in low assembly position

Instruction manual SIPLACE X-Series 3 Technical data and assemblies
From software version 713.0 Edition 11/2019 3.1 Performance data
105
3.1.5 SIPLACE X2 S machine performance
3
Placement head types SIPLACE SpeedStar (C&P20 P)
SIPLACE SpeedStar (C&P20 P2)
SIPLACE MultiStar (CPP)
SIPLACE TwinStar (TH)
Placement performance
SIPLACE X2 S
For a definition of placement performance values, see the note on page 101.
Placement
machine
Placement area 1 Placement area 2 IPC value Benchmark
value
X2 S-A C&P20 P C&P20 P 52,000 64,000
C&P20 P CPP_L 45,500 54,000
C&P20 P CPP_H 43,000 51,500
C&P20 P2 C&P20 P2 65,000 75,000
C&P20 P2 CPP_L 51,200 59,500
C&P20 P2 CPP_H 49,250 57,000
CPP_L CPP_L 37,400 44,000
CPP_H CPP_H 33,500 39,000
CPP_L CPP_H 35,450 41,500
X2 S-B C&P20 P TH 30,800 37,000
C&P20 P2 TH 37,000 42,500
CPP_L TH 23,200 27,000
CPP_H TH 21,250 24,500
X2 S-C TH TH 9,000 10,000
CPP_H = SIPLACE Multistar CPP in high assembly position
CPP_L = SIPLACE Multistar CPP in low assembly position