3 Technical data and assemblies Instruction manual SIPLACE X-Series 3.2 Ambient conditions and connection values From software version 713.0 Edition 11/2019 108 3.2.3 Compressed air supply and compressed air specificatio…

100%1 / 360
Instruction manual SIPLACE X-Series 3 Technical data and assemblies
From software version 713.0 Edition 11/2019 3.2 Ambient conditions and connection values
107
3.1.7 Component supply
3
3.2 Ambient conditions and connection values
3.2.1 Ambient conditions for packaging, transportation and storage
3
3.2.2 Environmental conditions for operation
3
Component supply Tracks occupied
4 component trolleys X on the SIPLACE X2 S / X3 S / X4 S
4 component trolleys X on the SIPLACE X4i S
160 feeder modules, each with 8 mm X
148 feeder modules, each with 8 mm X
Technical data
Tape reel diameter
Standard
Maximum
to 432 mm (17“)
483 mm (19“)
Component trolley changeover time < 1 minute
Temperature range Between -25°C and 55°C
Atmospheric humidity Up to 95%
Ambient pressure Up to 3000 m height without pressure equalization
Room temperature Between 15°C and 35°C
Atmospheric humidity 30% to 75%
(on average not higher than 45%, so that there is no risk of
condensation on the placement machine.)
Ambient pressure > 750 mbar (corresponds to 1700 m above mean sea level)
3 Technical data and assemblies Instruction manual SIPLACE X-Series
3.2 Ambient conditions and connection values From software version 713.0 Edition 11/2019
108
3.2.3 Compressed air supply and compressed air specification
3
Compressed air supply
Compressed air pressure val-
ues
p
min
p
max
0.5 MPa = 5.0 bar
1.0 MPa = 10 bar
Operating pressure 0.48 MPa ± 0.025 MPa (4.8 bar ± 0.25 bar)
Compressed air connection R 3/4" inner thread (pipe thread) with 1/2" hose connection
Compressed air consumption
*a
Placement head configuration
*b
Compressed air
consumption
with vacuum pump
*c
Compressed air con-
sumption
without vacuum
pump
*d
SIPLACE X4i S / X4 S
C&P20 P/C&P20 P/C&P20 P/C&P20 P
C&P20 P/C&P20 P/CPP/CPP
C&P20 P/C&P20 P/TH/TH
C&P20 P/C&P20 P/CPP_H
*e
/TH
CPP/CPP/CPP/CPP
CPP/CPP/CPP_H/TH
CPP/CPP/TH/TH
CPP/TH/TH/TH
TH/TH/TH/TH
260 Nl/min
370 Nl/min
330 Nl/min
350 Nl/min
480 Nl/min
460 Nl/min
440 Nl/min
420 Nl/min
400 Nl/min
990 Nl/min
720 Nl/min
680 Nl/min
700 Nl/min
480 Nl/min
460 Nl/min
440 Nl/min
420 Nl/min
400 Nl/min
SIPLACE X3 S
C&P20 P/C&P20 P/C&P20 P
C&P20 P/C&P20 P/CPP
C&P20 P/C&P20 P/TH
CPP/CPP/CPP
CPP / TH
CPP/TH/TH
TH/TH/TH
185 Nl/min
230 Nl/min
230 Nl/min
360 Nl/min
340 Nl/min
340 Nl/min
300 Nl/min
720 Nl/min
600 Nl/min
590 Nl/min
360 Nl/min
340 Nl/min
340 Nl/min
300 Nl/min
SIPLACE X2 S
C&P20 P / C&P20 P
C&P20 P/CPP
C&P20 P/TH
CPP / CPP
CPP / TH
TH / TH
130 Nl/min
185 Nl/min
165 Nl/min
240 Nl/min
220 Nl/min
200 Nl/min
480 Nl/min
360 Nl/min
340 Nl/min
240 Nl/min
220 Nl/min
200 Nl/min
Compressed air specification according to ISO 8573
Particle size 0.1 µm
Particle density 0.1 mg/m³
Maximum oil content
(class 1)
Particle density 0.01 mg/m³
Pressure dewpoint (class 4) Dewpoint + 3°
*)a Average consumption values. Under normal atmospheric conditions at 20°C and 1013 hPa.
*)b The compressed air values for the C&P20 P and the C&P20 P2 are identical.
*)c Optional
*)d Standard
*)e CPP_H = SIPLACE Multistar CPP in high assembly position
Instruction manual SIPLACE X-Series 3 Technical data and assemblies
From software version 713.0 Edition 11/2019 3.2 Ambient conditions and connection values
109
3.2.4 Electrical ratings and energy consumption
3
PLEASE NOTE
Use of a residual current protection device
The low ground leakage current of the system makes it possible to use an upstream
residual current protection device at the customer end. This must be all-current sen-
sitive (RCD type B).
SIPLACE X2 S
Electrical ratings
Supply voltage Fuse
Main power supply 3 x 380 V~ to 3 x 415 V~ ± 10 %; 50/60 Hz
3 x 200 V~ to 3 x 220 V~ ± 10 %; 50/60 Hz
*a
3 x 16A characteristic C
3 x 15A characteristic C
*b
Mains power con-
nection
Without cable
Cable 5 x 4 mm² WITH CEE plug, red 16 A (in accordance with IEC 60309) (3 x 380 V~ to 3 x 415 V~)
Cable 5 x 4 mm² WITHOUT plug (3 x 200 V~ to 3 x 220 V)
Short circuit rating (SCCR)
*c
10 kA
Energy consumption
With a vacuum pump
*d
With two vacuum pumps
d
Without vacuum pumps
*e
Nominal apparent
power
2.5 kVA -- 1.3 kVA
Nominal active
power
1.7 kW -- 1.0 kW
SIPLACE X3 S / X 4 S / X4i S
Electrical ratings
Supply voltage Fuse
Main power supply 3 x 380 V~ to 3 x 415 V~ ± 10 %; 50/60 Hz
3 x 200 V~ to 3 x 220 V~ ± 10 %; 50/60 Hz
a
3 x 16A characteristic C
3 x 15A characteristic C
b
Mains power con-
nection
Without cable
Cable 5 x 4 mm² WITH CEE plug, red 16 A (in accordance with IEC 60309) (3 x 380 V~ to 3 x 415 V~)
Cable 5 x 4 mm² WITHOUT plug (3 x 200 V~ to 3 x 220 V)
Short circuit rating (SCCR)*
c
10 kA
Energy consumption
With one vacuum pump
d
With two vacuum pumps
d
Without vacuum pumps
e
Nominal apparent
power
2.5 kVA 3.85 kVA 1.3 kVA
Nominal active
power
1.7 kW 2.45 kW 1.0 kW
*)a With options package
*)b e.g. Siemens circuit breakers in accordance with IEC and UL 489 (order no.: 5SJ4 316-7HG42)
or
EATON Industries circuit breaker FAZ-C16/3-NA 16A 3p (UL 489, CSA C22.2 no. 5, IEC 60947-2)
*)c With the original mains connection cable. The marked short circuit rating (SCCR) relates to the beginning of the original mains
cable. In the case of customer modifications, the factory-set length of the mains cable to the placement machine may not be
shortened nor the factory-set conductor cross-section increased, as this would have a negative impact on the short circuit rating
(SCCR).
*)d Vacuum pump for the C&P20 P / C&P20 P2 head only (optional)
*)e Standard