00198711-01_UM_X-Serie-S_EN.pdf - 第120页

3 Technical data and assemblies Instruction manual SIPLACE X-Series 3.5 Placement head From software version 713.0 Edition 11/2019 120 3.5.2.1 Overview 3 3 Fig. 3.5 - 2 SIPLACE SpeedSt ar - overview (1) Connection for th…

100%1 / 360
Instruction manual SIPLACE X-Series 3 Technical data and assemblies
From software version 713.0 Edition 11/2019 3.5 Placement head
119
3.5.2 SIPLACE SpeedStar C&P20 P2
The SIPLACE X-Series S uses the SIPLACE SpeedStar C&P20 P2 for top placement perfor-
mance.
3
CAUTION
Always take hold of the handle to push the placement head
The placement head may only be moved by pushing manually against the handle provid-
ed.
3 Technical data and assemblies Instruction manual SIPLACE X-Series
3.5 Placement head From software version 713.0 Edition 11/2019
120
3.5.2.1 Overview
3
3
Fig. 3.5 - 2 SIPLACE SpeedStar - overview
(1) Connection for the holding circuit of the vacuum pump
(2) "Intermediate distributor" board (under the cover)
(3) Handle
(4) Star motor
(5) DP drive
(6) Nozzle
(7) Pressure control valve
(8) Z motor (linear motor)
(9) Return cylinder
(5)
(1)
(7)
(2)
(3)
(4)
(6)
(8)
(9)
Instruction manual SIPLACE X-Series 3 Technical data and assemblies
From software version 713.0 Edition 11/2019 3.5 Placement head
121
3.5.2.2 Technical data for SIPLACE SpeedStar (C&P20 P2)
SIPLACE SpeedStar (C&P20 P2)
With component camera type 48
Component range
*a
*)a Please note that the placeable component range is also affected by the pad geometry, the customer-spe-
cific standards, the component packaging tolerances and the component tolerances.
0.12 mm x 0.12 (0201 metric) to 2220, Melf, SOT, SOD, Bare-Die,
Flip-Chip
Component spec.
Max. height
Min. lead pitch
Min. lead width
Min. ball pitch
Min. ball diameter
Min. dimensions
Max. dimensions
Max. weight
4 mm
70 µm
30 µm
100 µm
50 µm
0.12 mm x 0.12 mm
8.2 mm x 8.2 mm
1 g
Set-down force Touchless Placement, 1.3 N ± 0.5 N (standard)
0.5 N - 4.5 N
Nozzle types 40xx/60xx
X/Y accuracy
*b
*)b The accuracy values fulfill the conditions in the SIPLACE scope of supply and services.
± 35 µm/3σ
Angular accuracy ± 0.5° / 3σ
Illumination level 5