00198711-01_UM_X-Serie-S_EN.pdf - 第122页

3 Technical data and assemblies Instruction manual SIPLACE X-Series 3.5 Placement head From software version 713.0 Edition 11/2019 122 3.5.3 Sensor for the component reject bin The sensor for the component reject bin mon…

100%1 / 360
Instruction manual SIPLACE X-Series 3 Technical data and assemblies
From software version 713.0 Edition 11/2019 3.5 Placement head
121
3.5.2.2 Technical data for SIPLACE SpeedStar (C&P20 P2)
SIPLACE SpeedStar (C&P20 P2)
With component camera type 48
Component range
*a
*)a Please note that the placeable component range is also affected by the pad geometry, the customer-spe-
cific standards, the component packaging tolerances and the component tolerances.
0.12 mm x 0.12 (0201 metric) to 2220, Melf, SOT, SOD, Bare-Die,
Flip-Chip
Component spec.
Max. height
Min. lead pitch
Min. lead width
Min. ball pitch
Min. ball diameter
Min. dimensions
Max. dimensions
Max. weight
4 mm
70 µm
30 µm
100 µm
50 µm
0.12 mm x 0.12 mm
8.2 mm x 8.2 mm
1 g
Set-down force Touchless Placement, 1.3 N ± 0.5 N (standard)
0.5 N - 4.5 N
Nozzle types 40xx/60xx
X/Y accuracy
*b
*)b The accuracy values fulfill the conditions in the SIPLACE scope of supply and services.
± 35 µm/3σ
Angular accuracy ± 0.5° / 3σ
Illumination level 5
3 Technical data and assemblies Instruction manual SIPLACE X-Series
3.5 Placement head From software version 713.0 Edition 11/2019
122
3.5.3 Sensor for the component reject bin
The sensor for the component reject bin monitors whether the reject bin is seated correctly in its
mount.
If the reject bin was not inserted correctly, the placement machine cannot be started.
If the reject bin jumps out of its mount during the placement process, the placement machine
will be stopped immediately to avoid a head crash.
3.5.4 Vacuum pump (optional)
The vacuum pumps for the SIPLACE SpeedStar are fitted behind the COT inserts at locations 1
and 4, in the machine base. There are two types available:
Vacuum pump VX4.25
Vacuum pump VX4.25/0-47 IE3
3.5.4.1 Overview - type VX4.25
Item no. 03128463-xx Vacuum pump VX4.25
3
Fig. 3.5 - 3 Overview - vacuum pump
(1) Installation location for vacuum pump
(2) Vacuum pump VX 4.25
(1)
(2)
Instruction manual SIPLACE X-Series 3 Technical data and assemblies
From software version 713.0 Edition 11/2019 3.5 Placement head
123
3.5.4.2 Overview - type VX4.25/0-47 IE3
Item no. 03224400-xx Vacuum pump VX4.25/0-47 IE3
3
Fig. 3.5 - 4 Overview - vacuum pump
(1) Installation location for vacuum pump
(2) Vacuum pump VX 4.25 IE3
3.5.4.3 Safety instructions for vacuum pumps
3
3.5.4.4 Description
Only the SIPLACE SpeedStar can be operated with the vacuum pump. The SIPLACE SpeedStar
with vacuum pump is available as an option for the SIPLACE X-Series S.
When operated together with a vacuum pump, the compressed air consumption for the SpeedStar
(C&P20P/P2) head can be reduced considerably. A vacuum pump can supply up to two Speed-
Star (C&P20P/P2) heads. A maximum of two vacuum pumps can therefore be used (for 4x
C&P20P/P2). The running costs will fall according to the energy costs incurred.
(1)
(2)
WARNING
Please observe the safety instructions in the instruction manual supplied for the vac-
uum pump.