00198711-01_UM_X-Serie-S_EN.pdf - 第124页

3 Technical data and assemblies Instruction manual SIPLACE X-Series 3.5 Placement head From software version 713.0 Edition 11/2019 124 The vacuu m pump is sw itched on an d off with the plac ement mach ine. The station s…

100%1 / 360
Instruction manual SIPLACE X-Series 3 Technical data and assemblies
From software version 713.0 Edition 11/2019 3.5 Placement head
123
3.5.4.2 Overview - type VX4.25/0-47 IE3
Item no. 03224400-xx Vacuum pump VX4.25/0-47 IE3
3
Fig. 3.5 - 4 Overview - vacuum pump
(1) Installation location for vacuum pump
(2) Vacuum pump VX 4.25 IE3
3.5.4.3 Safety instructions for vacuum pumps
3
3.5.4.4 Description
Only the SIPLACE SpeedStar can be operated with the vacuum pump. The SIPLACE SpeedStar
with vacuum pump is available as an option for the SIPLACE X-Series S.
When operated together with a vacuum pump, the compressed air consumption for the SpeedStar
(C&P20P/P2) head can be reduced considerably. A vacuum pump can supply up to two Speed-
Star (C&P20P/P2) heads. A maximum of two vacuum pumps can therefore be used (for 4x
C&P20P/P2). The running costs will fall according to the energy costs incurred.
(1)
(2)
WARNING
Please observe the safety instructions in the instruction manual supplied for the vac-
uum pump.
3 Technical data and assemblies Instruction manual SIPLACE X-Series
3.5 Placement head From software version 713.0 Edition 11/2019
124
The vacuum pump is switched on and off with the placement machine. The station software auto-
matically takes into account an overrun time of 6 minutes, to prevent the motor overheating.
3
3.5.4.5 Maintenance instructions
Observe the additional maintenance instructions for the vacuum pump.
Read the relevant section in the maintenance manual for your placement machine.
PLEASE NOTE
The compressed air consumption values can be found in section 3.3
, page 110.
Instruction manual SIPLACE X-Series 3 Technical data and assemblies
From software version 713.0 Edition 11/2019 3.5 Placement head
125
3.5.5 SIPLACE MultiStar CPP
3
3
Fig. 3.5 - 5 SIPLACE MultiStar CPP - front view, function groups part 1
(1) Handle
(2) Star with 12 segments
(3) Segment with integrated DP drive
CAUTION
Always take hold of the handle to push the placement head
The placement head may only be moved by pushing manually against the handle provid-
ed.
(2)
(3)
(1)