5 Tasks at the placement machine Ins truction manual SIPLACE X-Series S 5.11 Observing displays on the feeder module From software version 713.0 Edition 11/2019 274 5.1 1 Observing displays on the feeder module 5 Fig. 5.…

Instruction manual SIPLACE X-Series S 5 Tasks at the placement machine
From software version 713.0 Edition 11/2019 5.10 Setting up the feeder modules
273
Pull the cover foil at the side of the pick-up window forward and out underneath the pick-up
window.
Fold the cover foil back until it lies against the pull-off edge (item 3 in fig. 5.10 - 5, page 272).
5
Push the lever (item 5 in fig. 5.10 - 5, page 272) back to lower the pickup window.
Guide the cover foil over the cover foil rocker (item 2 in fig. 5.10 - 7) until it reaches the foil
packing wheels (item 1 in fig. 5.10 - 7
).
5
Fig. 5.10 - 7 Guiding the cover foil to the foil packing wheels
(1) Cover foil packing wheels
(2) Cover foil
5
On the operator panel, press the FOIL button (item 3 in fig. 5.10 - 6, page 272) until the cover
foil is tensioned. The cover foil rocker points down and stops the drive motor.
Cut the component tape flush with the front end of the feeder module.
5.10.5 Configuring components on the SIPLACE SmartFeeder
The operation and setting up is described in the SIPLACE SmartFeeder X /Xi job guides.
PLEASE NOTE
Do not lower the pick-up window until the cover foil is lying against the pull-off edge.
(1)
(2)

5 Tasks at the placement machine Instruction manual SIPLACE X-Series S
5.11 Observing displays on the feeder module From software version 713.0 Edition 11/2019
274
5.11 Observing displays on the feeder module
5
Fig. 5.11 - 1 SIPLACE SmartFeeder X
(1) Operating panel - LED display
(2) Status display
(2)
(1)

Instruction manual SIPLACE X-Series S 5 Tasks at the placement machine
From software version 713.0 Edition 11/2019 5.11 Observing displays on the feeder module
275
5.11.1 Operating panel - LED display
The SIPLACE SmartFeeder have a multicolored status display for each track and LED displays,
to indicate the operating states.
5
Fig. 5.11 - 2 Buttons, LED and status displays: Example of SIPLACE SmartFeeder 2x8 mm
(1) SET button
(2) FOIL button
(3) BACK button
(4) FORWARD button
(5) Track change button for switching between right and left
(6) LED L left track active
(7) LED 1 mm increment for left track
(8) LED 2 mm increment for left track
(9) LED 4 mm increment for left track
(10) LED 8 mm increment for left track
(11) LED R right track active
(12) LED 1 mm increment for right track
(13) LED 2 mm increment for right track
(14) LED 4 mm increment for right track
(15) LED 8 mm increment for right track
(8)
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(9)
(10)
(15)
(14)
(13)
(12)
(11)