00198711-01_UM_X-Serie-S_EN.pdf - 第297页
Instruction manual SIPLACE X-Series S 6 Station extensions From software version 713.0 Edition 11/2019 6.1 Nozzle changer 297 6.1.2.5 T echnical data 6 6 Nozzle changer for the SIPLACE MultiSt ar CPP Number of ma gazines…

6 Station extensions Instruction manual SIPLACE X-Series S
6.1 Nozzle changer From software version 713.0 Edition 11/2019
296
6.1.2.4 Nozzle magazine for 28xx nozzles
6
Fig. 6.1 - 9 Nozzle magazine for 28xx nozzles
(1) 5 garages for 28xx nozzles with a maximum nozzle length of 12.5 mm
(garage numbers 1, 5, 6, 8 and 9)
(2) 4 garages for 28xx nozzles with a maximum nozzle length of 16.5 mm
(garage numbers 2, 3, , 4 and 7)
(3) Fiducials (only visible when locking plate open)

Instruction manual SIPLACE X-Series S 6 Station extensions
From software version 713.0 Edition 11/2019 6.1 Nozzle changer
297
6.1.2.5 Technical data
6
6
Nozzle changer for the SIPLACE MultiStar CPP
Number of magazines
*a*b
SIPLACE X2 S/X3 S/X4 S 6
SIPLACE X4i S 6
6
4
Number of nozzle garages
SIPLACE X2 S/X3 S/X4 S 6
SIPLACE X4i S 6
120
80
Standard configuration
SIPLACE X2 S/X3 S/X4 S 6
6
6
SIPLACE X4i S 6
80 x 20xx nozzle garages
1 magazine with 9 x 28xx nozzle garages
60 x 20xx nozzle garages
1 magazine with 9 x 28xx nozzle garages
Option: Nozzle changer "row 2" 4 magazines with 80 x Nozzle garages
Nozzle types 40xx, 11xx, 12xx
20xx, 28xx
*)a All magazines in the nozzle changer must be configured.
*)b With restrictions at location 2 for MTC/WPC

6 Station extensions Instruction manual SIPLACE X-Series S
6.1 Nozzle changer From software version 713.0 Edition 11/2019
298
6.1.2.6 Configuration example: CPP for SIPLACE X4i S
Locations 1, 2, 3 and 4 can each accommodate one nozzle changer for the CPP head (item 1 in
fig. 6.1 - 10
, page 298).
6
Fig. 6.1 - 10 Position of nozzle changer for the SIPLACE MultiStar CPP machine - configuration example
(SIPLACE X4i S)
6
6
(1) Nozzle changer
(2) SIPLACE MultiStar CPP
(3) Stationary cameras
(4) Nozzle changer row 2 (optional)
PLEASE NOTE
The placement machine stops if magazines are missing
In the event of missing or incorrectly positioned magazines, the safety circuit will stop the
placement machine.
Use all magazine places.
(2)(1)
(1)
(2)
(1)
(2) (2)
(3)
(3)
(1)
(4)
(4)