6 Station extensions Instruction manual SIPLACE X-Series S 6.4 Matrix tray changer From software versio n 713.0 Edition 11/2019 312 6.4.3 T echnical data 6.4.3.1 Dimensions, weight, other dat a 6 To w e r 1 ( X L ) To w …

100%1 / 360
Instruction manual SIPLACE X-Series S 6 Station extensions
From software version 713.0 Edition 11/2019 6.4 Matrix tray changer
311
6.4 Matrix tray changer
Item no. 00116438-xx SIPLACE Matrix Tray Changer (MTC)
6.4.1 Safety instructions
6
6
6.4.2 Description
The Matrix Tray Changer supports the storing and fully automatic changeover of up to 100 waffle
pack trays. The levels (storage positions in the towers) for the waffle pack trays are numbered up-
wards, from bottom to top.
The towers move independently of one another, in a vertical direction, until the selected magazine
reaches the access area of the feed axis. The horizontal feed axis transports the waffle pack tray
from the tower to the access area of the placement head.
Tower 1 has 30 levels, on each of which 2 JEDEC trays or one large tray up to a size of 240 x 340
mm² can be accommodated by the waffle pack tray carriers.
Tower 2 has a capacity of 40 levels for JEDEC trays.
The matrix tray changer has an integral chassis, and is easy to move to other locations. It is sup-
plied with the PCB conveyor height set for the customer-specific placement machine but can be
quickly and easily adapted to conveyor heights of 900, 930, and 950 mm.
WARNING
Risk of injuries!
Risk of injuries if you reach into the gap between the Matrix Tray Changer and the place-
ment machine base while the placement machine is running.
Do not reach into the gaps between the matrix tray changer and the placement ma-
chine base while the placement machine is running.
WARNING
Requirement for operation: Matrix Tray Changer docked onto the placement machine
Do not use the Matrix Tray Changer, if it is not docked onto the placement ma-
chine.
Only connect the power supply cable to the external power supply or only disconnect
it if the Matrix Tray Changer is docked onto the placement machine.
6 Station extensions Instruction manual SIPLACE X-Series S
6.4 Matrix tray changer From software version 713.0 Edition 11/2019
312
6.4.3 Technical data
6.4.3.1 Dimensions, weight, other data
6
Tower 1 (XL) Tower 2
Dimensions
Length x width
Height
1305 mm x 600 mm
1560 mm for 900 mm PCB conveyor height
1590 mm for 930 mm PCB conveyor height
1610 mm for 950 mm PCB conveyor height
Weight (basic package) Approx. 500 kg (with cassettes and waffle pack tray carri-
ers)
Weight (fully configured) Approx. 534 kg (with components)
Weight (moving loads) Approx. 80 kg Approx. 43.5 kg
Cassette size (L x W x H) 391.2 mm x 305.6 mm x
93.3 mm
352.7 mm x 154.8 mm x
133.8 mm
Cassette weight
(fully configured)
(without waffle pack tray carrier)
Approx. 11 kg
Approx. 1.7 kg
Approx. 7.5 kg
Approx. 1.35 kg
Weight of the waffle pack tray carrier 850 g 150 g
Dimensions of waffle pack tray carri-
er (L x W x H) 368 mm x 295.8 mm x
11.1 mm
371 mm x 146 mm x
10.1 mm
Distance from cassette to cassette 96 mm 135 mm
Distance from level to level 12 mm 11.8 mm
Vertical lift
444 mm (1st to 30th WTC
*a
)
511.2 mm (1st to 40th
WTC
a
)
Horizontal lift between transfer and
pickup position Approx. 647 mm Approx. 638 mm
Storage capacity 30 waffle pack tray carrier XL
with 60 JEDEC or
30 special magazines
of maximum size
40 waffle pack tray carriers
with 40 Jedec waffle pack
trays
Changeover time (over 5 levels) Approx. 2 s Approx. 1.5 s
Max. height of component and waffle
pack tray incl. tolerances
All levels occupied
One level free
Two levels free
8.5 mm
19,5 mm
31,5 mm
8.5 mm
19,5 mm
-
*)a Waffle pack tray carrier
Instruction manual SIPLACE X-Series S 6 Station extensions
From software version 713.0 Edition 11/2019 6.4 Matrix tray changer
313
6.4.3.2 Electrical ratings
6
6.4.3.3 Noise emissions
6
6.4.3.4 Permitted environmental factors
6
6.4.4 Installation notes for the MTC
In SIPLACE X2 S / X3 S / X4 S machines, an MTC can be docked onto location 2 in place of the
component trolley. To achieve this, the COT insert for the component trolley is replaced with the
docking unit for the MTC. If you want to use this MTC somewhere else, the free location can then
be configured again with a component trolley.
6
Supply voltage 3 x 200 V~ ± 5%; 50/60 Hz (Japan)
3 x 208 V~ ± 5%; 50/60 Hz (U.S.A.)
3 x 400 V~ ± 5%; 50/60 Hz (Europe)
Overall power 1.5 kW
Max. noise emissions 74 dB (A)
Room temperature Between 15°C and 35°C
Atmospheric humidity 30 to - 75 % (no higher than 45% on average to prevent
any possibility of condensation on the placement ma-
chine.)
PLEASE NOTE
Configuration options for MTC
The MTC can not be configured with a CPP head.
The MTC can only be configured at location 2 in SIPLACE X2 S / X3 S / X4 S ma-
chines.
SIPLACE X2 S / X3 S / X4 S machines must have a service flap installed. See “Po-
sition of protective switches on the placement machine” on page 81.
The MTC can be configured with the Twin Head and the stationary cameras of type
33, 25 or the 3D coplanarity sensor.
Only 12 nozzle magazines can be used for configurations with an MTC.