Instruction manual SIPLACE X-Series S 2 Operational safety
From software version 713.0 Edition 11/2019 2.6 Safety features
85
There are three conditions that must be fulfilled in order to activate the safety cutoff (CBS):
All protective features and the EMERGENCY STOP buttons must be released.
The start button must have been pressed.
The „software release“ or „control ON„ signal must be set by the control software.
2.6.4.1 Overview of safety cutoff
When the placement machine is ready for operation, the contacts of all position switches and the
EMERGENCY STOP buttons are unlocked. If a protective cover, for example, is raised, the cor-
responding switch and safety cutoff will be triggered. For the operator's information, this status
change is signaled to the control computer via a digital CAN bus input signal from the I/O control
unit. An error message to this effect appears on the user interface.
Prerequisites 2
The following conditions must be fulfilled in order to start and operate the placement machine:
All component trolleys must be docked into place.
All protective covers on the placement machine must be closed.
The two emergency STOP buttons must be released.
The minimum operating pressure must have been reached.
The software release ("Control ON") must be enabled.
If one of the start buttons is now pressed, the safety cutoff (CBS) will switch the safety-controlled
supply voltages on and the placement machine will be ready for operation.
Safety cutoff components 2
The following components are monitored by the safety cutoff:
Position switch for the four protective covers on the placement machine
Two EMERGENCY STOP buttons on the placement machine
Position switch for the COT inserts on the placement machine
Waffle pack changer (optional)
2 Operational safety Instruction manual SIPLACE X-Series S
2.6 Safety features From software version 713.0 Edition 11/2019
86
2
Fig. 2.6 - 9 EMERGENCY STOP loops
Start button pressed.
No
No
Yes
No
No
Yes
Yes
2
Active
Safety cutoff No
Voltage
Y axis 0 V
X axis 0 V
Star axis 0 V
DP axis 42V-
Z axis (C&P, TH) 42 V-
Z axis (CPP) 0 V-
Active
PCB conveyor No
Lifting table No
PCB clamp No
Width adjustment No
Tape cutter No
COT insert Yes
Yes
Compressed
air min. 0.5 MPa
(5.0 bar)?
EMERGENCY STOP button
pressed?
- Protective cover and/or
service flap open?
Component trolley
EMERGENCY STOP circuit
interrupted?
2
Active
Safety cutoff Yes
Voltage
Y axis 300 V-
X axis 300 V-
Star axis 160 V-
DP axis 42 V-
Z axis (C&P, TH) 42 V-
Z axis (CPP) 160 V-
Active
PCB conveyor Yes
Lifting table Yes
PCB clamp Yes
Width adjustment Yes
Tape cutter Yes
COT insert Yes
Instruction manual SIPLACE X-Series S 2 Operational safety
From software version 713.0 Edition 11/2019 2.6 Safety features
87
2.6.4.2 Enabling the EMERGENCY STOP
If problems occur, the SIPLACE X-Series S can be stopped by pressing the EMERGENCY STOP
button.
An EMERGENCY STOP can be triggered by:
Pressing one of the EMERGENCY STOP buttons on the placement machine
In these cases, the safety cutoffs are triggered and the power contactors will be switched off within
100 ms or 500 ms (STOP category 1, controlled shutdown with interruption of power supply during
downtime).
2.6.4.3 Resetting an EMERGENCY STOP
To reset an EMERGENCY STOP, unlock the EMERGENCY STOP button.
Find out the reason why the EMERGENCY STOP button triggered.
Remove the cause.
Unlock the relevant EMERGENCY STOP button.
2.6.4.4 Resetting the lock
Close the open protective cover.
2.6.4.5 Triggering the lock
Opening the protective cover.