2.7.5 Compressed air conditions after switching off at the main switch
When the main switch is switched off or the mains supply to the placement machine fails, the elec-
trically-controlled main valve of the compressed air unit will close (item 1 in fig. 2.8 - 1
, page 94 ).
The pressure will drop to 0 MPa (0 bar) within 5 seconds. The components before the electrically-
controlled main valves will remain pressurized.
Instruction manual SIPLACE X-Series S 2 Operational safety
From software version 713.0 Edition 11/2019 2.8 Disabling the compressed air supply and discharging the pressure
93
2.8 Disabling the compressed air supply and discharging
the pressure
The compressed air unit is located in the sector distributor of location 1 (see fig. 4.2 - 1, page 192
). The working pressure of the placement machine is set to 0.50 ± 0.025 MPa (5.0 ± 0.25 bar). The
position of the compressed air unit is shown at item 1 in fig. 2.8 - 1
, page 94. The supply of com-
pressed air to the placement machine can be interrupted with the shutoff valve (item 2 in fig. 2.8
- 1, page 94 ).
Use the machine key to release the cover lock.
Lift the cover (see fig. 2.8 - 1, page 94 ).
Turn the lever of the shutoff valve (item 1 of fig. 2.8 - 1, page 94) from the vertical to the hor-
izontal position.
Monitor the operating pressure manometer (item 5 in fig. 2.8 - 1, page 94 ). When the place-
ment machine is switched on, the pressure discharges to 0 MPa (0 bar) within 1 minute.
2
CAUTION
Interruption to compressed air supply!
When the placement machine is switched on, do not use the stop valve to interrupt
the compressed air supply for more than 30 minutes.
If you need to shut off the pneumatic system for longer in order to carry out preven-
tive maintenance or servicing work, you must switch the placement machine off at
the main switch and disconnect it from the power supply.
2 Operational safety Instruction manual SIPLACE X-Series S
2.8 Disabling the compressed air supply and discharging the pressure From software version 713.0 Edition 11/2019
94
2
Fig. 2.8 - 1 Compressed air unit on the placement machine
Legend for fig. 2.8 - 1
(1) Manometer for the machine component supply pressure
Target pressure: 0.5 ± 0.025 MPa, 5 ± 0.25 bar (display range 0 - 1.0 MPa, 0 - 10 bar)
(2) Manometer for supply pressure of gantries 1 to 4
Target pressure: 0.46 ± 0.01 MPa, 4.6 ± 0.1 bar (display range 0 - 1.0 MPa, 0 - 10 bar)
(3) Manometer for inlet pressure
Target pressure: 0.5 - 1.0 MPa, 5 - 10 bar (display range: 0 - 1.0 MPa, 0 - 10 bar)
(4) Stop valve in the "OPEN" position
(5) Compressed air filter
(6) Compressed air connection
2
WARNING
Risk of injuries!
Risk of injuries from pressurized compressed air lines.
NEVER detach compressed air lines while they are still pressurized.
(6)
(1)
(2)
(3)
(5)
(4)