00196378-0102_UM X-Feeder_EN - 第88页

Messages Messages for 8 - 88 mm Feeder Modules Messages Sent by the Feede r Module 88 User Manual X Feeder Modules SIPLACE Family 5.2.1.21 Download Boot 5.2.1.22 Update Boot 5.2.1.23 New Parameters 5.2.1.24 EEPROM Read E…

100%1 / 108
Messages
Messages Sent by the Feeder Module Messages for 8 - 88 mm Feeder Modules
User Manual X Feeder Modules SIPLACE Family 87
5.2.1.16 Foil Jam
5.2.1.17 Remove the Foil
5.2.1.18 CAN Bus Error
5.2.1.19 Boot Error
5.2.1.20 Data Flash Error
LCD, de:
LCD, en:
Folienstau
Foil Jam
Status display: red
Cause: The foil motor is blocked because the foil disposal rolls are unable to move easily.
They are probably being blocked by the trapped foil
Solution: Remove the foil, empty the foil container and clean the foil disposal rolls.
LCD, de:
LCD, en:
Folie entf.
Remove Foil
Status display: orange
Cause: You have selected a function which is invalid while the cover foil is tensioned. The
foil rocker has been pushed down.
Solution: If you want to perform this function, remove the foil from the pair of toothed wheels
and cut it, to relax the foil rocker.
LCD, de:
LCD, en:
CANBusFehler
CANBusError
Status display: Red
Cause: CAN bus error, the feeder module is unable to communicate with the machine
(FCU).
Solution: Log out and on again, check the fibre optic cable interface.
If a reset does not help, please send the feeder module to ASM Assembly
Systems.
Comments: Clean the fibre optic cable interface
The fibre optic cable is a transparent plastic cable for transmitting light
Note: Include the component table in your error search!
LCD, de:
LCD, en:
BootFlashErr
BootFlashErr
Status display: red
Cause: Unable to correctly write data in boot or application memory.
Solution: Repeat the download of the boot software.
If the error persists: Download the application software first and then the boot soft-
ware.
If the error persists: Replace the control board of the feeder module.
Comments: This error will only appear during of after a boot software download.
LCD, de:
LCD, en:
DataFlashErr
DataFlashErr
Status display: red
Cause: Unable to write data in the data memory
Solution: Log the feeder module out and on.
If the error persists: Replace the control board of the feeder module.
Comments: The display text may also be FlashDataErr.
Messages
Messages for 8 - 88 mm Feeder Modules Messages Sent by the Feeder Module
88 User Manual X Feeder Modules SIPLACE Family
5.2.1.21 Download Boot
5.2.1.22 Update Boot
5.2.1.23 New Parameters
5.2.1.24 EEPROM Read Error
5.2.1.25 EEPROM Write Error
LCD, de:
LCD, en:
DownloadBoot
DownloadBoot
Status display: red
Cause: Data are being written from the data memory into the cache memory.
Solution: Wait
LCD, de:
LCD, en:
Update Boot
Update Boot
Status display: red
Cause: Data are being written from the cache memory into the boot memory.
Solution: Wait
LCD, de:
LCD, en:
ParameterNeu
New Default
Status display: orange
Cause: The feeder module software is automatically setting default parameters. This is
performed, for example, after loading new software and takes approx. 5 seconds.
Solution: Wait
LCD, de:
LCD, en:
EEP-ReadErr
EEP-ReadErr
Status display: red
Cause: Data was not read from the EEPROM correctly
Solution: Remove the tape. Acknowledge the error with the SET button. Then acknowledge
the request to perform a reference run with the yellow button. If this message con-
tinues to appear, you will need to replace the control board or the drive.
Comments: Since the position of the drive is stored in the EEPROM, a reference run is
necessary in these cases.
LCD, de:
LCD, en:
EEP-WriteErr
EEP-WriteErr
Status display: red
Cause: Data backup has not been performed correctly in the EEPROM.
Solution: Remove the tape. Acknowledge the error with the SET button. Then acknowledge
the request to perform a reference run with the yellow button. If this message con-
tinues to appear, you will need to replace the control board or the drive.
Comments: Since the position of the drive is stored in the EEPROM, a reference run is
necessary in these cases.
Messages
Messages From Process Messages for 8 - 88 mm Feeder Modules
User Manual X Feeder Modules SIPLACE Family 89
5.2.1.26 EEPROM Data Error
5.2.1.27 Scan Request
5.2.2 Messages From Process
5.2.2.1 Introduction
The following messages are only shown by the feeder module. The display text itself is generated by the
station computer and is then transmitted via the CAN bus to the LCD display of the feeder module. The
error source is therefore not in the feeder module but usually in the placement machine state. For exam-
ple, pickup or Vision errors, which affect the component of a particular track, will be displayed on the
feeder module for that track. The following table shows the LCD display text, the color and mode of the
status display, the cause and troubleshooting measures.
5.2.2.2 Not Verified
5.2.2.3 Scan Barcode
LCD, de:
LCD, en:
EEP-DataErr
EEP-DataErr
Status display: red
Cause: The data back-up in the EEPROM was not carried out completely
Solution: Remove the tape. Acknowledge the error with the SET button. Acknowledge the
prompt for a reference run with the yellow button.
If the message continues to appear, you will need to replace the control board or
the drive.
Comments: Since the position of the drive is stored in the EEPROM, a reference run is
necessary in these cases.
LCD, de:
LCD, en:
Scan Anford.
Scan Request
Status display: - - -
Cause: The request to perform scanning has been sent by the feeder module to the MC
(Machine Controller).
Solution: - - -
Comments: After the grey SET button has been pressed (1 sec.) the display shows the
Scan Anford. / Scan Request message for approx. 2 sec. to indicate that
the feeder module has sent a request for barcode scanning to the MC. If a barcode
system is active, the MC will then send the Scan Barcode display text to the
feeder module.
From version 1.24
LCD, de:
LCD, en:
NichtGeprueft
Not verified
Status display:
Cause: The tape has been inserted but the barcode has not yet been scanned.
Solution: Scan the barcode.
Comments: This message is only shown if a barcode system has been installed and is active.
LCD, de:
LCD, en:
Scan Barcode
Scan Barcode
Status display:
Cause: The barcode still needs to be scanned.
Solution: Scan the barcode.
Comments: - - -