00196378-0102_UM X-Feeder_EN - 第91页
Messages Messages From Process Messages for 8 - 88 mm Feeder Modules User Manual X Feeder M odules SIPLACE Family 91 5.2.2.9 Pickup Error 5.2.2.10 Target Directory Full 5.2.2.11 External Deactivation 5.2.2.12 Refill 5.2.…

Messages
Messages for 8 - 88 mm Feeder Modules Messages From Process
90 User Manual X Feeder Modules SIPLACE Family
5.2.2.4 Scan OK
5.2.2.5 Scan Error
5.2.2.6 Fill level Too Low
5.2.2.7 Splice Sensor
5.2.2.8 Vision Error
LCD, de:
LCD, en:
Scan OK
Scan OK
Status display:
Cause: Barcode scanning was successful.
Solution: - - -
Comments: - - -
LCD, de:
LCD, en:
Scan Fehler
Scan Not OK
Status display:
Cause: Barcode scanning was not successful.
Solution: Scan the barcode again.
Comments: Check the quality of the barcode label.
LCD, de:
LCD, en:
Fuell. Niedrig
Low Filling
Status display:
Cause: Warning issued when fill level is too low
Solution: Splice on new component reel and update fill level.
Comments: This message is only shown if a component level indicator has been installed and
is active.
LCD, de:
LCD, en:
SpleissSensor
SpliceSensor
Status display:
Cause: Warning issued when the splice sensor is missing.
Solution: Provide a feeder module with splice sensor or switch off the component level indi-
cator in the station software, if this is not being used.
Comments: The splice sensor in a feeder module is only required by the placement machine if
a component on this track is subject to a component level indicator or traceability
function.
LCD, de:
LCD, en:
VisionFehler
Vision Error
Status display:
Cause: The component on this track has not been correctly recognized by the image
processing tool or the component is defective.
Solution: Check the geometry of the component with the Vision data
Comments: This requires an exact analysis of the pickup process, as this error message could
have several causes.

Messages
Messages From Process Messages for 8 - 88 mm Feeder Modules
User Manual X Feeder Modules SIPLACE Family 91
5.2.2.9 Pickup Error
5.2.2.10 Target Directory Full
5.2.2.11 External Deactivation
5.2.2.12 Refill
5.2.2.13 Wrong Type
LCD, de:
LCD, en:
Abhol Fehler
Pickup Error
Status display:
Cause: The component on this track was not correctly picked up by the placement head.
The track was disabled.
Solution: Check the nozzle vacuum.
Comments: This requires an exact analysis of the pickup process, as this error message could
have several causes.
LCD, de:
LCD, en:
Verz. Voll
Target Full
Status display:
Cause: The data folder (spool), for an external operating data recording system, is full.
Unable to save Traceability or GEM data.
Solution: This message can only be reset in the external system (HOST).
Comments: - - -
LCD, de:
LCD, en:
Extern Deak.
Extern Deac.
Status display:
Cause: The track was disabled externally (e.g. through setup verification).
Solution: The track needs to be re-enabled by the external system.
Comments: - - -
LCD, de:
LCD, en:
Nachfuellen
Refill
Status display:
Cause: The track has been disabled because a deactivation threshold was reached.
Solution: Splice on new components for the relevant track (refill trays) and set the track to
"full".
Comments: A warning threshold has been exceeded e.g. by the level checker.
LCD, de:
LCD, en:
Falscher Typ
Wrong Type
Status display:
Cause: A different feeder module type is set in the programming system to that set in the
machine.
Solution: Correct the feeder module type or change the current setup in the programming
system.
Comments: The machine can recognize a feeder module at the location. However, this does
not match that specified in the current setup.

Messages
Messages for 8 - 88 mm Feeder Modules Messages From Process
92 User Manual X Feeder Modules SIPLACE Family
5.2.2.14 Location Error
5.2.2.15 Foil Tension
LCD, de:
LCD, en:
Place Fehler
Place error
Status display:
Cause: The feeder module has not been placed in position or communication to the feeder
module does not function properly.
Solution: Set the feeder module up according to the programming system requirements.
Check the interface to the FCU (EDIF).
Comments: The machine is unable to recognize the feeder module.
LCD, de:
LCD, en:
Folienspann.
Foil Tension
Status display:
Cause: Foil tension is too low.
Solution: Insert the tape and tension the foil.
Comments: - - -