All Ids on SIPLACE are 6 or 7-digits long. The last 3 digits are a consecutively increasing
integer. The next two digits distinguish between errors, event and variables (0:Event,
1:ErrorEvent; 2:Variable) and the software component (0:GEM, 1:Realtimesoftware;
2:Stationsoftware). The first 2 represent the „object“ on which the event occurs.
Example:
6 1 2 007 (Transportwidth)
The objects are :
ObjectId Name
1 Software
2 Nozzle Changer
3Axis
4 Fiducials
5 Vision
6 Transport
7 Coplanarity
8 Matrix Tray Changer (MTC)
9 Barcode
10 GEM-Kernel
11 User Interface / Operator
12 CAN-Bus
13 Revolver Head 1
14 Revolver Head 2
15 IC-Head
16 Data Preparation
17 Trolleys
18 Glue Machine
19 CRDL Measurement
20 Miscellaneous
21 Flux
25 Traceability
Object: Transport
Realtimesoftware
Variable
Number
SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02
HOST Interface Manual
©Siemens AG, all rights reserved page 155 of 243
VID Class Format Name and Description
Fiducials
412002 SV L FIDUCIALDATA
Result from the last fiducial measurement
<L
<U1 FiducalName>
<I1 Quality> [1 - 100]
<U4 X-position> [1/1000 mm]
<U4 Y-position> [1/1000 mm]
<U4 X-deviation> [1/1000 mm]
<U4 Y-deviation> [1/1000 mm]
>
In case of an ink spot x-position, y-position, x-
deviation, y-deviation and quality are not valid.
For a detailed description of the data item see „4.2
Data Item Dictionary“.
An empty list indicates an error.
SIPLACE Transport
612001 SV U1 INPUTCONVEYORSTATE
The state of the input conveyor.
0 = Empty
1 = Full
2 = Error
612012 SV U1 FIRSTPROCESSINGCONVEYORSTATE
The state of the first processing conveyor.
0 = Empty
1 = Full
2 = Error
612013 SV U1 INTERMEDIATECONVEYORSTATE
The state of the intermediate conveyor
0 = Empty
1 = Full
2 = Error
612014 SV U1 SECONDPROCESSINGCONVEYORSTATE
The state of the second processing conveyor.
0 = Empty
1 = Full
3 = Error
4
SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02
HOST Interface Manual
Page 156 of 243 ©Siemens AG, all rights reserved
VID Class Format Name and Description
612003 SV U1 OUTPUTCONVEYORSTATE.
The state of output conveyor.
0 = Empty
1 = Full
2 = Error
612004 SV U1 TWININPUTCONVEYORSTATE.
The state of the input conveyor on twin side
0 = Empty
1 = Full
2 = Error
612022 SV U1 TWINFIRSTPROCESSINGCONVEYORSTATE
The state of the first processing conveyor on twin side
0 = Empty
1 = Full
2 = Error
612023 SV U1 TWININTERMEDIATECONVEYORSTATE
The state of the intermediate conveyor on twin side
0 = Empty
1 = Full
2 = Error
612024 SV U1 SECONDPROCESSINGCONVEYORSTATE
The state of the second processing conveyor on twin
side
0 = Empty
1 = Full
2 = Error
612006 SV U1 TWINOUTPUTCONVEYORSTATE.
The state of output conveyor on twin side.
0 = Empty
1 = Full
2 = Error
612007 SV I4 TRANSPORTWIDTH
transport width [1/1000 mm]
A value of -1 indicates an error
Only valid after width has been measured or adjusted
by line computer
612008 SV I4 TWINTRANSPORTWIDTH
transport width [1/1000 mm] on twin side
A value of -1 indicates an error