00193368-02 - 第160页

SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02 HOST Inter fac e Manual Page 160 of 243 ©Siemens AG, all rights reser ved VID Class Format Name and Descrip tion SIPLACE. 1002057 SV U1 CO NTROLMO DE The ac…

100%1 / 243
SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02
HOST Interface Manual
©Siemens AG, all rights reserved page 159 of 243
VID Class Format Name and Description
Control State Model
1002005 EC U1 INITCONTROLSTATE.
Initial (power-up) control superstate.
1 = Off-Line
2 = On-Line
1002006 SV U1 CONTROLSTATE.
The current Control State.
1 = Off-Line/Equipment Off-Line
2 = Off-Line/Attempt On-Line
3 = Off-Line/Host Off-Line
4 = On-Line/Local
5 = On-Line/Remote
1002007 SV U1 PREVIOUSCONTROLSTATE.
The Control State in effect before the most recent
transition to the current Control State.
1 = Off-Line/Equipment Off-Line
2 = Off-Line/Attempt On-Line
3 = Off-Line/Host Off-Line
4 = On-Line/Local
5 = On-Line/Remote
1002008 EC U1 ONLINEFAILED.
The default Control State transition when Attempt On-
Line fails.
1 = Equipment Off-Line
3 = Host Off-Line
1002009 EC U1 ONLINESUBSTATE.
The default (power-up) online substate of the Control
State Model.
4 = Local
5 = Remote
1002010 EC U1 OFFLINESUBSTATE.
The default (power-up) offline substate of the Control
State Model.
1 = Equipment Off-Line
2 = Attempt On-Line
3 = Host Off-Line
1002056 SV A OPERATORCMDINRMOTESTATE
The last command issued by the Operator while the
Control state is „Remote“.
An empty text indicates that there was no operator
command in remote state since the last start of the
SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02
HOST Interface Manual
Page 160 of 243 ©Siemens AG, all rights reserved
VID Class Format Name and Description
SIPLACE.
1002057 SV U1 CONTROLMODE
The actual control mode at the SIPLCAE. This SV
indicates which software system is allowed to
download placement programs.
1 = none
2 = the „GEM-Host“
3 = the line computer (LCU)
Process State Model
1002011 SV U1 PROCESSSTATE.
The current Process State.
0 = Machine Initialization
1 = Single Function
2 = Processing
1002012 SV U1 PREVIOUSPROCESSSTATE.
The Process State in effect before the most recent
transition to the current Process State.
0 = Machine initialization
1 = Single Function
2 = Processing
Alarm Management
1002013 SV U4 ALARMID.
The ALID of the most recent Alarm transition.
1002014 SV U1 ALARMSTATE.
The Alarm State now in effect for the most recently
transitioned alarm.
0 = Alarm transitioned OFF
1 = Alarm transitioned ON
1002015 SV U4 ALARMSERIAL.
The sequence number of the most recent alarm
change (going on or going off). This number starts at
zero at power-up and increments by one for each
alarm transition which occurs.
1002016 DV A[0-40] ALARMTEXT.
The Alarm Text (ALTX) for the most recently
transitioned Alarm.
1002018 EC U1 CONFIGALARMS.
An EC which controls which Alarm Report message
this Equipment will send.
SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02
HOST Interface Manual
©Siemens AG, all rights reserved page 161 of 243
VID Class Format Name and Description
0 = S5F1
1 = S5F71
2 = S5F73
1002019 EC U1 WBITS5.
An EC which controls the W-Bit setting used when
sending Alarm Reports (S5F1, S5F71, or S5F73).
0 = W-Bit not set
1 = W-Bit set
1002020 SV L ALARMSENABLED.
A list of all Alarms which are currently enabled.
Format as follows:
<L
<U4 ALID>
...
>
1002021 SV L ALARMSSET.
A list of all Alarms which are currently in the SET (on)
state. Format as follows:
<L
<U4 ALID>
...
>
Time and date
1002022 SV A CLOCK.
The Equipment's current Date and Time in the
following format: YYYYMMDDhhmmsscc.
YYYY = year
MM = month
DD = day
hh = hours
mm = minutes
ss = seconds
cc = centiseconds
1002023 SV A TIME.
The Equipment's current date and time. Format is
described in the variable GEMTIMEFORMAT (VID
1002065). It may be either
YYYYMMDDhhmmsscc OR YYMMDDhhmmss
YY(YY) = year
MM = month