SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02 HOST Inter fac e Manual ©Siemens AG, all rights reser ved page 161 of 243 VID Class Format Name and Descrip tion 0 = S5F1 1 = S5F71 2 = S5F73 1002019 EC U1 W…

SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02
HOST Interface Manual
Page 160 of 243 ©Siemens AG, all rights reserved
VID Class Format Name and Description
SIPLACE.
1002057 SV U1 CONTROLMODE
The actual control mode at the SIPLCAE. This SV
indicates which software system is allowed to
download placement programs.
1 = none
2 = the „GEM-Host“
3 = the line computer (LCU)
Process State Model
1002011 SV U1 PROCESSSTATE.
The current Process State.
0 = Machine Initialization
1 = Single Function
2 = Processing
1002012 SV U1 PREVIOUSPROCESSSTATE.
The Process State in effect before the most recent
transition to the current Process State.
0 = Machine initialization
1 = Single Function
2 = Processing
Alarm Management
1002013 SV U4 ALARMID.
The ALID of the most recent Alarm transition.
1002014 SV U1 ALARMSTATE.
The Alarm State now in effect for the most recently
transitioned alarm.
0 = Alarm transitioned OFF
1 = Alarm transitioned ON
1002015 SV U4 ALARMSERIAL.
The sequence number of the most recent alarm
change (going on or going off). This number starts at
zero at power-up and increments by one for each
alarm transition which occurs.
1002016 DV A[0-40] ALARMTEXT.
The Alarm Text (ALTX) for the most recently
transitioned Alarm.
1002018 EC U1 CONFIGALARMS.
An EC which controls which Alarm Report message
this Equipment will send.

SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02
HOST Interface Manual
©Siemens AG, all rights reserved page 161 of 243
VID Class Format Name and Description
0 = S5F1
1 = S5F71
2 = S5F73
1002019 EC U1 WBITS5.
An EC which controls the W-Bit setting used when
sending Alarm Reports (S5F1, S5F71, or S5F73).
0 = W-Bit not set
1 = W-Bit set
1002020 SV L ALARMSENABLED.
A list of all Alarms which are currently enabled.
Format as follows:
<L
<U4 ALID>
...
>
1002021 SV L ALARMSSET.
A list of all Alarms which are currently in the SET (on)
state. Format as follows:
<L
<U4 ALID>
...
>
Time and date
1002022 SV A CLOCK.
The Equipment's current Date and Time in the
following format: YYYYMMDDhhmmsscc.
YYYY = year
MM = month
DD = day
hh = hours
mm = minutes
ss = seconds
cc = centiseconds
1002023 SV A TIME.
The Equipment's current date and time. Format is
described in the variable GEMTIMEFORMAT (VID
1002065). It may be either
YYYYMMDDhhmmsscc OR YYMMDDhhmmss
YY(YY) = year
MM = month

SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02
HOST Interface Manual
Page 162 of 243 ©Siemens AG, all rights reserved
VID Class Format Name and Description
DD = day
hh = hours
mm = minutes
ss = seconds
(cc = centiseconds)
Terminal Service
1002034 EC U1 WBITS10.
An EC which controls the W-Bit setting used when
sending S10F1.
0 = W-Bit not set
1 = W-Bit set
Data Collection
1002030 SV U4 PREVIOUSCEID.
The CEID of the most recent Collection event which
has occurred.
1002031 EC BOOL RPTYPE.
This EC controls some aspects of the format of Event
Reports sent by this Equipment.
FALSE = Normal Event Reports
TRUE = Annotated Event Reports
1002032 EC U1 CONFIGEVENTS.
An EC which controls some aspects of the Event
Reports sent by this Equipment.
0 = S6F9 or S6F3
1 = S6F11 or S6F13
1002033 EC U1 WBITS6.
An EC which controls the W-Bit setting used when
sending stream six messages (events, trace)
0 = W-Bit not set
1 = W-Bit set
1002035 SV L EVENTSENABLED.
A list of all Events which are currently enabled.
Format as follows:
<L
<U4 CEID>
...
>
1002036 DV U4 ECIDCHANGE.
The VID of the Equipment Constant most recently