00193368-02 - 第176页

SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02 HOST Inter fac e Manual Page 176 of 243 ©Siemens AG, all rights reser ved VID Class Format Name and Descrip tion <U4 X-position > [1/1000 mm] <U4 Y…

100%1 / 243
SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02
HOST Interface Manual
©Siemens AG, all rights reserved page 175 of 243
VID Class Format Name and Description
<I4 open_nozzle>
<I4 closed_nozzle>
<I4 cubic_nozzle>
<I4 not_cubic_nozzle>
<I4 tol_dirty_nozzle>
<I4 tol_leaky_nozzle>
>
.....
>
The first element in this list refers to segment 1, the
second to segment 2 and so on.
tol_dirty_nozzle and tol_leaky_nozzle are currently not
used.
For a detailed description of the data item see „4.2
Data Item Dictionary“.
An empty list indicates an error.
1412007 SV L SEGMENTINFOREV2
Summation of information per segment.
<L
<L
<I2 CompPickedUp>
<I2 PickUpErrors>
<I2 CompPlaced>
<I2 PlaceErrors>
>
.....
>
The first element in this list refers to segment 1, the
second to segment 2, and so on.
The variable can be linked e.g. to event PCBReady. It
is reseted when a PCB reaches the center conveyor.
For a detailed description of the data item see „4.2
Data Item Dictionary“.
1412008 SV L PLACEINFOREV2SUB1
Subset of PLACEINFOREVx variable. Detailed
description see there.
<L
L <
SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02
HOST Interface Manual
Page 176 of 243 ©Siemens AG, all rights reserved
VID Class Format Name and Description
<U4 X-position> [1/1000 mm]
<U4 Y-position> [1/1000 mm]
<F8 Angle> [1/100 degrees]
<U1 ForceIndex>
<A ReferenceDesignator>
<A ComponentName>
<U2 PackageFormNumber>
<U1 PlacementResult>
<I4 PlacementVacuum> [mbar]
<U2 DataValid>
<I4 X-deviation> [1/1000 mm]
<I4 Y-deviation> [1/1000 mm]
<F8 Angle> [1/100 degrees]
<F8 MaxLeadDev>
<F8 MaxBallDev>
>
....
(for each segment)
... .
>
The first element in this list refers to segment 1, the
second to segment 2 and so on. If a segment was not
in use in the last placement cycle the list for that
segment is left empty.
Miscellaneous
2012013 SV U2 ERRORTYPE
Type of the most recent error
2 Transport
3 Track error
4 Machine error
5 Miscellaneous
A value of 0 indicates an error.
2012014 SV U2 GANTRYONERROR
Gantry associated with the most recent error (1...4)
A value of 0 indicates an error.
2012015 SV U2 SEGMENTONERROR
Segment number associated with the most recent
SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02
HOST Interface Manual
©Siemens AG, all rights reserved page 177 of 243
VID Class Format Name and Description
error (1...12)
A value of 0 indicates an error.
2012016 SV U2 TRACKONERROR
Track number associated with the most recent error
event
A value of 0 indicates an error.
2012017 SV U2 ERRORINFO1
Additional information about an error event.
Corresponds to the first parameter of an error
message on the station computer.
2012018 SV U2 ERRORINFO2
Additional information about an error event.
Corresponds to the second parameter of an error
message on the station computer.
2012021 SV L GANTRYHEADCONFIG
<L
<L
<I2 GantryGroupID
<L
<L
<I2 GantryID>
<I2 TypeOfGantry>
<L
<L
<I2 HeadID>
<I2 HEADTYPE>
>
...
>
>
...
>
>
TypeOfGantry:
At the moment there is only 1 Type of Gantry.
TypeOfGantry is always = 1
HEADTYPE:
5 = Revolverhead with 12 nozzles