00193368-02 - 第190页

SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02 HOST Inter fac e Manual Page 190 of 243 ©Siemens AG, all rights reser ved VID Class Format Name and Descrip tion <L <L <A ComponentName> <I2 …

100%1 / 243
SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02
HOST Interface Manual
©Siemens AG, all rights reserved page 189 of 243
VID Class Format Name and Description
L <
<U4 X-position> [1/1000 mm]
<U4 Y-position> [1/1000 mm]
<F8 Angle> [1/100 degrees]
<U1 ForceIndex>
<A ReferenceDesignator>
<A ComponentName>
<U2 PackageFormNumber>
<U1 PlacementResult>
<I4 PlacementVacuum> [mbar]
<I4 Vacuum> [mbar]
<U2 DataValid>
<I4 X-deviation> [1/1000 mm]
<I4 Y-deviation> [1/1000 mm]
<F8 Angle> [1/100 degrees]
<U1 Quality> [0 - 100]
<U4 Length> [1/1000 mm]
<U4 Width> [1/1000 mm]
<L
<I4 Pitch_per_lead_group>
....
<I4 Pitch_per_lead_group>
>
<F8 MaxLeadDev>
<F8 MaxBallDev>
<F8 OrthoDev> [degrees]
<U2 LeadCount>
>
.....
>
The first element in this list refers to segment 1, the
second to segment 2 and so on. If a segment was not
in use in the last placement cycle the list for that
segment is left empty
For a detailed description of the data item see „4.2
Data Item Dictionary“.
An empty list indicates an error.
2412004 SV L PICKUPINFOREV4
Pick-up information for revolver head 4
SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02
HOST Interface Manual
Page 190 of 243 ©Siemens AG, all rights reserved
VID Class Format Name and Description
<L
<L
<A ComponentName>
<I2 TrackNumber>
<U2 FeederType>
<I2 Level>
<I2 Division>
<U1 Location>
<U1 PickUpResult>
<I4 PickUpVacuum> [mbar]
<i4 Vacuum>
>
....
>
The first element in this list refers to segment 1, the
second to segment 2 and so on. If a segment was not
in use in the last pick up cycle the list for that segment
is left empty.
If the component was picked up from a feeder
Level
will contain -1.
In the case that the component was picked up from a
tray in the matrix tray changer
TrackNumber will
contain the
Tower of the MTC(1,2). In this way
PICKINFOREVx has the same format as in previous
versions.
For a detailed description of the data item see „4.2
Data Item Dictionary“.
An empty list indicates an error.
2412005 SV L NOZZLECONF4
Nozzle configuration on revolver head 3. Only valid
after reference run.
<L
<L
<U4 NOZZLE_TYPE>
<I4 REAL_NOZZLE_LENGTH> [1/1000 mm]
>
......
>
The nozzle length is measured during the reference
run. It depends on the HEIGHTREVOLVER1 value. So
SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02
HOST Interface Manual
©Siemens AG, all rights reserved page 191 of 243
VID Class Format Name and Description
REAL_NOZZLE_LENGTH is not a absolute but a
relative value.
It is calculated by subtracting the measured distance
between the nozzle and the upper edge of the
transport conveyor from the HEIGHTREVOLVER1
value.
An empty list indicates an error.
For a detailed description of the data item see „4.2
Data Item Dictionary“.
2412006 SV L VACUUMDATAREV4
Vacuum measurements from the last reference run on
revolver head 3. Valid only after reference run.
<L
<L
<I4 open_nozzle> [mbar]
<I4 closed_nozzle> [mbar]
<I4 cubic_nozzle> [mbar]
<I4 not_cubic_nozzle> [mbar]
<I4 tol_dirty_nozzle> [mbar]
<I4 tol_leaky_nozzle> [mbar]
>
.....
>
The first element in this list refers to segment 1, the
second to segment 2, and so on.
tol_dirty_nozzle and tol_leaky_nozzle are currently not
used.
An empty list indicates an error.
For a detailed description of the data item see „4.2
Data Item Dictionary“.
2412007 SV L SEGMENTINFOREV4
Summation of information per segment
<L
<L
<I2 CompPickedUp>
<I2 PickUpErrors>
<I2 CompPlaced>
<I2 PlaceErrors>
>