00193368-02 - 第219页

SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02 HOST Inter fac e Manual ©Siemens AG, all rights reser ved page 219 of 243 CEID Nam e Descrip tio n 611063 FM_GUI_T EXT_F_UEBERG_BB1 Error upon PCB tr ansf er…

100%1 / 243
SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02
HOST Interface Manual
Page 218 of 243 ©Siemens AG, all rights reserved
CEID Name Description
610068 PCBreachedSecondProcessing
Conveyor2
The light barrier of the conveyor 2
(processing 2 area) signals the arrival
of a PCB
1
610036 PCBreachedOutputConveyor2 The light barrier of the output
conveyor 2 signals the arrival of a
PCB.
1
610037 TransportWidthMeasured The SIPLACE finished the
measurement of the
<TRANSPORTWIDTH> (initiated by
line computer)
4
610044 TransportWidthMeasured2 The SIPLACE finished the
measurement of the
<TWINTRANSPORTWIDTH>on
conveyor 2 (initiated by line computer)
4
610051 TakeOutInConv A PCB was taken out of the input
conveyor 1
1
610069 TakeOutProcessing1Conv A PCB was taken out of the conveyor
1 (processing 1 area)
1
610070 TakeOutIntermediateConv A PCB was taken out of the
intermediate conveyor 1
1
610071 TakeOutProcessing2Conv A PCB was taken out of the conveyor
1 (processing 2 area)
1
610052 TakeOutOutConv A PCB was taken out of the output
conveyor 1
1
610053 TakeOutInConv2 A PCB was taken out of the input
conveyor 2
1
610072 TakeOutProcessing1Conv2 A PCB was taken out of the conveyor
2 (processing 1 area)
1
610073 TakeOutIntermediateConv2 A PCB was taken out of the
intermediate conveyor 2
1
610074 TakeOutProcessing2Conv2 A PCB was taken out of the conveyor
2 (processing 2 area)
1
610054 TakeOutOutConv2 A PCB was taken out of the output
conveyor 2
1
611025 FM_LSAUT_VERFAHRBER Conveyor belt target width outside
travel range*
611030 FM_LSK_MAX_SCHRITT Proximity switch not found during
conveyor belt width check*
611031 FM_LSK_PROXIMITY
SWITCH_N_FREI
Proximity switch switched before
conveyor belt width check*
611059
FM_GUI_TEXT_F_UEBERN_EB
Error upon PCB transfer in input
conveyor
611060
FM_GUI_TEXT_F_UEBERG_EB
Error upon PCB transfer in input
conveyor
611061
FM_GUI_TEXT_F_LP_LANG_EB
Overlength PCB in input conveyor
611062
FM_GUI_TEXT_F_UEBERN_BB1
Error upon PCB transfer in processing
conveyor 1
SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02
HOST Interface Manual
©Siemens AG, all rights reserved page 219 of 243
CEID Name Description
611063
FM_GUI_TEXT_F_UEBERG_BB1
Error upon PCB transfer in processing
conveyor 1
611064
FM_GUI_TEXT_F_HT1_TIMEOUT
Lifting table 1 Timeout
611065
FM_GUI_TEXT_F_HT1_BERO1
Lifting table 1 Bero 1 defective
611066
FM_GUI_TEXT_F_HT1_BERO2
Lifting table 1 Bero 2 defective
611067
FM_GUI_TEXT_F_HT1_
DREHRICHT
Lifting table 1 incorrect direction of
rotation
611068 FM_GUI_TEXT_F_STOPPER1 Stopper ahead (Processing area 1)
defect
611069 FM_GUI_TEXT_F_ZENTR1 Error ceramic substrate centering 1
611070 FM_GUI_TEXT_F_LP_
ZURUECK_BB1
Pull back PCB in first processing
conveyor
611071 FM_GUI_TEXT_F_LP_LANG_
BB1
Overlength PCB in first processing
conveyor
611072 FM_GUI_TEXT_F_LP_ENTNO
MMEN_BB1
PCB removed from first processing
conveyor in automatic mode
611073 FM_GUI_TEXT_F_UEBERN_ZB Error upon PCB transfer in
intermediate conveyor
611074
FM_GUI_TEXT_F_UEBERG_ZB
Error upon PCB transfer in
intermediate conveyor
611075
FM_GUI_TEXT_F_LP_LANG_ZB
Overlength PCB in intermediate
conveyor
611076
FM_GUI_TEXT_F_UEBERN_BB2
Error upon PCB transfer in second
processing conveyor
611077
FM_GUI_TEXT_F_UEBERG_BB2
Error upon PCB transfer in second
processing conveyor
611078
FM_GUI_TEXT_F_HT2_TIMEOUT
Lifting table 2 timeout
611079 FM_GUI_TEXT_F_HT2_BERO1 Lifting table 2 Bero 1 defective
611080 FM_GUI_TEXT_F_HT2_BERO2 Lifting table 2 Bero 2 defective
611081 FM_GUI_TEXT_F_HT2_DREH
RICHT
Lifting table 2 incorrect direction of
rotation
611082 FM_GUI_TEXT_F_STOPPER2 Stopper at the back (processing area
2) defect
611083 FM_GUI_TEXT_F_ZENTR2 Error ceramic substrate centering 2
611084 FM_GUI_TEXT_F_LP_ZURUEC
K_BB2
Pull back PCB in second processing
conveyor
611085
FM_GUI_TEXT_F_LP_LANG_BB2
Overlength PCB second processing
conveyor
611086
FM_GUI_TEXT_F_LP_ENTNOMME
N_BB2
PCB removed from processing
conveyor 2 in automatic mode
611087
FM_GUI_TEXT_F_UEBERN_AB
Error upon PCB transfer in output
conveyor
SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02
HOST Interface Manual
Page 220 of 243 ©Siemens AG, all rights reserved
CEID Name Description
611088
FM_GUI_TEXT_F_UEBERG_AB
Error upon PCB transfer in output
conveyor
611089
FM_GUI_TEXT_F_LP_LANG_AB
Overlength PCB in output conveyor
611090 FM_GUI_TEXT_F_BRV_MIN Width adjustment at limit switch
minimum width
611091 FM_GUI_TEXT_F_BRV_MAX Width adjustment at limit switch
maximum width
611092 FM_GUI_TEXT_TSP_EF_LP_E
NTFERNEN
Conveyor already occupied (remove
PCB)
611093 FM_GUI_TEXT_TSP_EF_LP_EI
NLEGEN
Conveyor not occupied (load PCB)
611094 FM_GUI_TEXT_TSP_EF_LP_W
EITERE
Conveyor occupied by other PCBs
(remove PCBs)
611095 FM_GUI_TEXT_TSP System error from conveyor control
611096 FM_GUI_TEXT_TSPNOPRG System error: No program loaded
611097 FM_GUI_TEXT_TSPRAMNOK System error: Faulty RAM
611098 FM_GUI_TEXT_TSPCMDNOK System error: command unknown
611099 FM_GUI_TEXT_TSPBUSY System error: command is not being
accepted
611100 FM_GUI_TEXT_TSPPARFALSE System error: parameter value range
exceeded
611101
FM_GUI_TEXT_TSPLPNRFALSE
System error: unknown PCB no.
transmitted
611102 FM_GUI_TEXT_TSPLPWEITER System error: PCB has already been
enabled
611103 FM_GUI_TEXT_TSPLPOPTION
SFALSE
System error: incorrect options for
PCB
611104 FM_GUI_TEXT_TSPNOLP System error: no PCB available
611105 FM_GUI_TEXT_TSPLPVORHA
NDEN
System error: PCB already exists
611106
FM_GUI_TEXT_TSPLPGEKLEMMT
System error: PCB already clamped
611107
FM_GUI_TEXT_TSPNOTAUS
Emergency stop actuated
611108
FM_GUI_TEXT_TSPFLASHNOK
System error in Flash RAM
611109
FM_GUI_TEXT_
TSPLPAUSFAHREN
PCB not transported out of machine
611110 FM_GUI_TEXT_TSPNOINIT Conveyor not initialized
611111 FM_GUI_TEXT_TSPHUNKNO
WMESSAGE
System error: unknown acknowledge
from transport
611112 FM_GUI_TEXT_TSPHANSWER
FORMAT
System error: synchr. feedback too
short
611113 FM_GUI_TEXT_TSPHCNV
BANDNR
System error: invalid conveyor number