00193368-02 - 第227页
SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02 HOST Inter fac e Manual ©Siemens AG, all rights reser ved page 227 of 243 CEID Name Descri ption SYNC_CALL c omm unic ation (CCAN_NOK) 1211040 FM_GUI_TEX T_T…

SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02
HOST Interface Manual
Page 226 of 243 ©Siemens AG, all rights reserved
CEID Name Description
1211007 FM_CAN_BUS_OFF CAN bus: switched out*
1211008
FM_CAN_FHL_NR_UNBEKANNT
CAN bus: unknown error number*
1211013
FM_CAN_MSG_LS_ZHS_FALSE
Star can't be turned due to light
barrier z-top*
1211014
FM_CAN_MSG_SM_DPS_FALSE
Star can't be turned due to d-axis
feed drive*
1211015
FM_CAN_MSG_SM_ZHS_FALSE
Star can't be turned due to pick-
up/place valve actuator*
1211016
FM_CAN_MSG_SM_BAS_FALSE
Star can't be turned due to ejection
valve actuator*
1211017 FM_CAN_MSG_LS_ZHS_
START_XY
RV: Gantry can't be moved due to
light barrier z-top*
1211019 FM_CAN_MSG_ZHS_ABH RV: Fault in pick-up/place valve
actuator during pick-up*
1211020 FM_CAN_MSG_LS_Z_O_ABH_
SP
RV: Light barrier z-top not triggered
during pick-up*
1211022 FM_CAN_MSG_ZHS_BST RV: Fault in pick-up/place valve
actuator during placement*
1211023 FM_CAN_MSG_LS_Z_O_BST_S
P
RV: Light barrier z-top not triggered
during placement*
1211025 FM_CAN_MSG_VAKUUM_
MESS_SP
RV: vacuum cannot be measured
1211026
FM_CAN_MSG_BLASL_MESS_SP
RV: forced air cannot be measured
1211027
FM_CAN_MSG_VAKUUM_AUS_SP
RV: vacuum cannot be switched
off
1211028
FM_CAN_MSG_VAKUUM_EIN_SP
RV: vacuum cannot be switched on
1211029
FM_CAN_MSG_BLASL_EIN_SP
RV: forced air cannot be switched
on
1211030
FM_CAN_MSG_BLASL_AUS_SP
RV: forced air cannot be switched
off
1211031 FM_CAN_MSG_INIT_Z Valve adjustment drive pick-
up/placement cannot be initialized
1211032 FM_CAN_MSG_INIT_D RV/D axis: feeder drive cannot be
initialized
1211033 FM_CAN_MSG_INIT_ABW Valve adjustment drive ejection
cannot be initialized
1211034 FM_CAN_MSG_BELEUCHT_BE
_SP
RV: component camera
illumination cannot be operated
1211037 FM_CAN_MSG_BELEUCHT_LP Board camera illumination cannot
be operated
1211038 FM_CAN_MSG_FHL_NR_
UNBEK_SP
RV: unknown error number from
head board
1211039 FM_GUI_TEXT_TI_CCAN_NO_ System error in CAN

SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02
HOST Interface Manual
©Siemens AG, all rights reserved page 227 of 243
CEID Name Description
SYNC_CALL communication (CCAN_NOK)
1211040 FM_GUI_TEXT_TI_CCANDL_
NO_SYNC_CALL
System error in CAN
communication (CCANDL_NOK)
1211041
FM_GUI_TEXT_TI_CAN_M_NOK
Component table: Error in
communication with CAN bus (no
status signal)
1211042
FM_GUI_TEXT_TI_CAN_M_BUSY
Component table: Error in
communication with CAN bus
(overload)
1211043
FM_GUI_TEXT_TI_CAN_M_TIME_
OUT
Component table: Error in
communication with CAN bus
(timeout)
1211044 FM_GUI_TEXT_TI_CAN_M_NO
_PROG
Component table: Error in
communication with CAN bus (no
program)
1211045 FM_GUI_TEXT_TI_CAN_M_CM
D_FALSE
Component table: Error in
communication with CAN bus
(incorrect command)
1211046 FM_GUI_TEXT_TI_CAN_M_NO
_TARGET
Component table: Error in
communication with CAN bus
(incorrect receiver)
1211047 FM_GUI_TEXT_TI_CAN_WRON
G_QUITT
Component table: Unknown
acknowledgment from CAN bus
1211048 FM_GUI_TEXT_TI_CAN_WR_Q
UITT_L
Component table: Incorrect length
of acknowledgment message from
CAN bus
1211049 FM_GUI_TEXT_TI_CCAN_NO_
NORM
System error (CCAN_NO_NORM)
1211050 FM_GUI_TEXT_TI_CCAN_NO_
VIRT
System error (CCAN_NO_VIRT)
1211051
FM_GUI_TEXT_GS_CAN_M_NOK
Tape cutting unit: Error in
communication with CAN bus (no
status signal)
1211052
FM_GUI_TEXT_GS_CAN_M_BUSY
Tape cutting unit: Error in
communication with CAN bus
(overload)
1211053 FM_GUI_TEXT_GS_CAN_M_TI
ME_OUT
Tape cutting unit: Error in
communication with CAN bus
(timeout)
1211054 FM_GUI_TEXT_GS_CAN_M_N
O_PROG
Tape cutting unit: Error in
communication with CAN bus (no
program)
1211055 FM_GUI_TEXT_GS_CAN_M_C
MD_FALSE
Tape cutting unit: Error in
communication with CAN bus
(incorrect command)
1211056 FM_GUI_TEXT_GS_CAN_M_N
O_TARGET
Tape cutting unit: Error in
communication with CAN bus
(incorrect command)

SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02
HOST Interface Manual
Page 228 of 243 ©Siemens AG, all rights reserved
CEID Name Description
1211057 FM_GUI_TEXT_GS_CAN_WRO
NG_QUITT
Tape cutting unit: Unknown
acknowledgment from CAN bus
1211058 FM_GUI_TEXT_GS_CAN_WR_
QUITT_L
Tape cutting unit: Incorrect length
of acknowledgment message from
CAN bus
1211060 FM_GUI_TEXT_CAN_NO_SLIO System error (CAN_NO_SLIO)
1211061 FM_GUI_TEXT_CAN_SLIO_NO
_RESPONSE
System error
(CAN_SLIO_NO_RESPONSE)
1211062 FM_GUI_TEXT_CAN_ABORT_E
RROR
System error
(CAN_ABORT_ERROR)
1211063 FM_GUI_TEXT_CAN_SETOUTP
UTBITS
System error
(CAN_SETOUTPUTBITS)
1211064 FM_GUI_TEXT_CAN_RESETO
UTPUTBITS
System error
(CAN_RESETOUTPUTBITS)
1211065 FM_GUI_TEXT_CAN_PIN_BLIN
KT_SCHON
System error
(CAN_BLINKT_SCHON)
1211066 FM_GUI_TEXT_CAN_SLIO_DE
STRUCTOR_WAIT
System error
(CAN_SLIO_DESTRUCTOR_WAI
T)
1211067 FM_GUI_TEXT_CAN_SLIO_CO
NSTRUCTOR_ERR
System error
(CAN_SLIO_CONSTRUCTOR_ER
ROR)
1211068 FM_GUI_TEXT_CAN_NO_INPU
T_PIN
System error
(CAN_NO_INPUT_PIN)
1211069 FM_GUI_TEXT_CAN_NO_OUT
PUT_PIN
System error
(CAN_NO_OUTPUT_PIN)
1211070 FM_GUI_TEXT_CAN_INVALID_
PORTNAME
System error
(CAN_INVALID_PORTNAME)
1211071 FM_GUI_TEXT_CAN_INVALID_
SLIONAME
System error
(CAN_INVALID_SLIONAME)
1211072 FM_GUI_TEXT_CAN_NO_DL_O
BJECT
System error
(CAN_NO_DL_OBJECT)
1211073 FM_GUI_TEXT_CAN_DL_SYNC
CALL_ERROR
System error
(CAN_DL_SYNCCALL_ERROR)
1211074 FM_GUI_TEXT_CAN_DL_KEIN_
OK
System error (CAN_DL_KEIN_OK)
1211075 FM_GUI_TEXT_CAN_SLIO_NIC
HT_ERLAUBT
Invalid SLIO number
1211076 FM_GUI_TEXT_CAN_RECV_O
HNE_SEND
System error
(CAN_RECV_OHNE_SEND)
1211077 FM_GUI_TEXT_CAN_SEND_O
HNE_RECV
System error
(CAN_SEND_OHNE_RECV)
1211078 FM_CAN_SYSTEM_ERROR General system error
1211079 FM_CAN_WARNING Repeated disruptions in the CAN
bus.