CEID Name Description
1611136 FM_GF_DATA_STORE Error upon saving GF data
1611137 FM_MK_DATA_STORE Error upon saving MK data
1611138 FM_GUI_TEXT_MA_ERR_READING_R
EAL_MA
Error reading REAL.MA file
1611139 FM_GUI_TEXT_MA_ERR_WRITING_R
EAL_MA
Error writing REAL.MA file
1611140 FM_GUI_TEXT_LP_NO_VERM_DATA No measuring data available
1611141 FM_GUI_TEXT_BB_HO_MA_DAT_ERR Error in machine data supply
1611142 FM_GUI_TEXT_BB_HO_RS_DAT_ERR Error in setup data supply
1611143 FM_LRR_DA_MA Error in the machine data
1611144 FM_SIPRO_COMM_CONF Communication error or
configuration error with
SIPLACE Pro
* Depending on the collection event, some of the status variables <ERRORTYPE>,
<GANTRYONERROR>, <SEGMENTONERROR>, <TRACKONERROR>,
<ERRORINFO1> and <ERRORINFO2> will be updated at each of these CAN-bus
collection events.
Trolley
CEID Name Description
1711005
FM_WAG_F_KOMM_UNTERBR
Communication table-feeder
interrupted*
1711017
FM_GUI_TEXT_TI_CCAN_NO_TISCH
Component table: System error
(CCAN_NO_TISCH)
1711018
FM_GUI_TEXT_TI_CCAN_NO_GS
Tape cutting unit: System error
(CCAN_NO_GS)
1711019
FM_GUI_TEXT_TI_CCAN_NO_DIAG_T
I
Component table: System error
(CCAN_NO_DIAG_TI)
1711020
FM_GUI_TEXT_TI_CCAN_NO_DIAG_
GS
Tape cutting unit: System error
(CCAN_NO_DIAG_GS)
1711021
FM_GUI_TEXT_TI_CCAN_NO_SIMU
Component table: System error
(CCAN_NO_SIMU)
1711022
FM_GUI_TEXT_TI_NO_TISCHKAL
System error (NO_TISCHKAL)
1711023
FM_GUI_TEXT_TI_BE_KEIN_ZIEL
Component table: System
configuration error
(BE_KEIN_ZIEL)
1711024
FM_GUI_TEXT_TI_GS_KEIN_ZIEL
Tape cutting unit: System
configuration error
(GS_KEIN_ZIEL)
1711025
FM_GUI_TEXT_GS_CAN_GENERAL
Tape cutting unit: General error
· Depending on the collection event, some of the status variables <ERRORTYPE>,
<GANTRYONERROR>, <SEGMENTONERROR>, <TRACKONERROR>,

SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02
HOST Interface Manual
Page 232 of 243 ©Siemens AG, all rights reserved
<ERRORINFO1> and <ERRORINFO2> will be updated at each of these trolley
collection events.
Filling Level
CEID Name Description
1711030 FM_FK_TRACK_RUN_LOW_MIN The track will run empty in a few
minutes.
1711031
FM_FK_TRACK_RUN_LOW_VALUE
The track will run empty because the
amount is below the minimum
amount.
1711032 FM_FK_TRACK_RUN_LOW_PER
CENT
The track will run empty because the
amount is at the percentile
minimum.
1711035 FM_FK_TRACK_ISEMPTY_PERC
ENT
The track has been deactivated
because the amount is below the
percentile minimum
1711036 FM_FK_TRACK_INACT_BC The track has been deactivated
because the barcode of one
component is incorrect.
· Depending on the collection event, some of the status variables <ERRORTYPE>,
<GANTRYONERROR>, <SEGMENTONERROR>, <TRACKONERROR>,
<ERRORINFO1> and <ERRORINFO2> will be updated at each of these trolley
collection events.
Miscellaneous
CEID Name Description
2010001 CoverOpen The protective covers was opened 1
2010002 CoverClosed The protective covers was closed 1
2010004 TrackFull Track reset to full
MACHINESIDE <2012022>,
LOCATION <2012035>,
TRACKNUMBER <2012023>
are valid
LOCATION = -1 means that all tracks of
all locations have been refilled
TRACKNUMBER = -1 means that all
tracks of the specified location have been
refilled
1
2010005 TrackEmpty Track set to empty
In the case of a feeder (not MTC)
TRACKNUMBER <2012023>,
SEGMENT <2012026>,
MACHINESIDE <2012022>,
LOCATION <2012035>
are valid
1

SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02
HOST Interface Manual
©Siemens AG, all rights reserved page 233 of 243
2010006 RefRunGantry1 Reference run complete for the gantry 1
axis
1
2010007 RefRunGantry2 Reference run complete for the gantry 2
axis
1
2010008 TableDownload Software downloaded to the table and
<SOFTWAREREVTABLE> will be
updated.
23
2010009 SingleCircuitOmit The machine signals that it found a single
circuit to omit (Ink Punkt)
Variables HEADID (VID 1022030),
GANTRYID (2012028) and
GANTRYDROUPID (2012029)
are valid.
1
2010010 TapeCut1 Tape cut at location 1 1
2010011 TapeCut2 Tape cut at location 2 1
2010015 MachineReStarted SIPLACE station is re-booting 1
2010016 PickupError An Pickup-Error has occured and
<SEGMENT>, <COMPONENTNAME>,
<MASCHINESIDE>, <LOCATION>,
<TRACKNUMBER>, <DIVISION>,
<LEVEL>, <GANTRYID>,
<GANTRYGROUPID> and <HEADID>
will be updated
28
2010017 PlaceError An Place-Error has occured and
<SEGMENT>,
<REFERENCEDESIGNATOR>,
<COMPONENTNAME>, <GANTRYID>,
<GANTRYGROUPID>, <HEADID>,
<PACKAGEFORMNUMBER> and
<PLACEERRORDESCRIPTION> will be
updated
29
2010018 RefRunGantry3 Reference run complete for the gantry 3
axis
1
2010019 RefRunGantry4 Reference run complete for the gantry 4
axis
1
2010033 MTCDownload Software downloaded to the MTC and
<SOFTWAREREVMTC> will be updated.
23
2010021 PCBstartProc1Conv1 Start of the placement process for the
PCB in the conveyor 1 processing area 1
<GANTRYINFOREV1>,
<GANTRYINFOREV4>,
<SEGMENTINFO1 >,
<SEGMENTINFO4>
will be resetted.
1
2010022 PCBreadyProc1Conv1 Placement is finished for the PCB in the
conveyor 1 processing area 1.
1
2010023 PCBstartProc2Conv1 Start of the placement process for the
PCB in the conveyor 1 processing area 2
<GANTRYINFOREV2>,
<GANTRYINFOREV3>,
1