00193368-02 - 第44页

SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02 HOST Inter fac e Manual Page 44 of 243 ©Siemens AG, all rights reser ved 3.7 Equipment Terminal Services The SIPLACE s upports exc hange of f ree text mes s…

100%1 / 243
SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02
HOST Interface Manual
©Siemens AG, all rights reserved page 43 of 243
The Events with a '2' at the end of the Event name (e.g., PCBreachedOutputConveyor2)
refer to the 2
nd
belt of a dual conveyor.
Collection Event CEID
HS50,
HS60
S25HM,
S27HM
PCBreachedInputConveyor 610031
4 4
PCBreachedFirstProcessingConveyor 610061
4 4
PCBreachedIntermediateConveyor 610062
4
PCBreachedSecondProcessingConveyor 610063
4
PCBreachedOutputConveyor 610033
4 4
PCBreachedInputConveyor2 610034
4 4
PCBreachedFirstProcessingConveyor2 610066
4 4
PCBreachedIntermediateConveyor2 610067
4
PCBreachedSecondProcessingConveyor2 610068
4
PCBreachedOutputConveyor2 610036
4 4
TransportWidthMeasured 610037
4 4
TransportWidthMeasured2 610044
4 4
TakeOutInConv 610051
4 4
TakeOutProcessing1Conv 610069
4 4
TakeOutIntermediateConv 610070
4
TakeOutProcessing2Conv 610071
4
TakeOutOutConv 610052
4 4
TakeOutInConv2 610053
4 4
TakeOutProcessing1Conv2 610072
4 4
TakeOutIntermediateConv2 610073
4
TakeOutProcessing2Conv2 610074
4
TakeOutOutConv2 610054
4 4
SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02
HOST Interface Manual
Page 44 of 243 ©Siemens AG, all rights reserved
3.7 Equipment Terminal Services
The SIPLACE supports exchange of free text messages with the Host (SECS Stream 10).
This Equipment accepts the following messages from the Host, and responds accordingly
if the W-Bit is set to 1:
S10F3 /* Single Line Data */
S10F5 /* Multi-Line Data */
S10F9 /* Broadcast */
The message text will be displayed on the Equipment's CRT. Collection Event S10Ack
(CEID 1000002) occurs once the operator has acknowledged the message and an Event
Report will be sent to the Host (if enabled).
The S10F3 and S10F9 are restricted to a single TEXT data item, but S10F5 can contain
multiple TEXT data items. Each TEXT data item is limited to 160 characters. Each data
item in S10F5 will be displayed on a separate line at the equipment.
If the Operator has not acknowledged an existing message when the Host sends another
message, the new message will be displayed and the old one discarded.
The Host can send a message with a 0-length text to clear the Operator text display.
Also, the Equipment allows the operator to send a single block message to the Host via
S10F1. The maximum length of this text is 160 characters. The S10F2 response from
the Host is ignored.
3.7.1 Related Variables
There are no relevant variable for the Equipment Terminal Capability.
3.7.2 Related Collection Events
There is one CEID related to the Equipment Terminal Capability. For a more complete
listing of these collection events, please see "Appendix B -- Collection Events".
Collection Event CEID
HostMsgAckr 1000002
SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02
HOST Interface Manual
©Siemens AG, all rights reserved page 45 of 243
3.8 Error Messages
The SIPLACE provides standard Stream 9 messages to report SECS-II errors. See 4.9
"SECS Message Detail" for detailed description of these messages:
S9F1 Unrecognized Device ID
S9F3 Unrecognized Stream
S9F5 Unrecognized Function
S9F7 Invalid Data
S9F9 Transaction Timeout
S9F11 Data Too Long
3.8.1 Related Variables
There are no Variables relevant for Error Messages.
3.8.2 Related Collection Events
There are no CEID related to Error Messages.