00193368-02 - 第59页

SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02 HOST Inter fac e Manual ©Siemens AG, all rights reser ved page 59 of 243 3 = Message to long (m or e than 160 char) 4 - 63 reserved used in : S10F2, S10F4, S…

100%1 / 243
SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02
HOST Interface Manual
Page 58 of 243 ©Siemens AG, all rights reserved
4.2 Data Item Dictionary
Remarks:
'used in' lists the Events or Variables in which the individual data items are used. Here,
the `x' is used as a substitute for a number of like variables. For example,
PICKINFOREVx stands for: PICKINFOREV1, PICKINFOREV2, PICKINFOREV3 and
PICKINFOREV4
ABS - Any binary string
Format : B
used in : S2F25, S2F26
ACKC5 - Acknowledge Code
Format: B[1]
0 = Accepted
>0 = error, not accepted
1 - 63 reserved
used in : S5F2, S5F73
ACKC6 - Acknowledge Code
Format: B[1]
0 = Accepted
>0 = error, not accepted
1 - 63 reserved
used in : S6F2, S6F3, S6F10, S6F12, S6F14
ACKC7 - Acknowledge Code
Format: B[1]
0 = Accepted
1 = Permission not granted
2 = Length error
3 = Matrix overflow
4 = PPID not found
5 = Mode unsupported
6 = busy
7 = Control state is not „remote“
8 = Control mode is not „GEM-Host“
9 = recipe type is not binary
10 - 63 reserved
used in : S7F4, S7F18
ACKC10 - Acknowledge Code
Format: B[1]
0 = Accepted for display
1 = Message will not be displayed
2 = Terminal not available
SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02
HOST Interface Manual
©Siemens AG, all rights reserved page 59 of 243
3 = Message to long (more than 160 char)
4 - 63 reserved
used in : S10F2, S10F4, S10F6, S10F10
ALCD - Alarm code byte
Format: B[1]
bit 8 = 1 means alarm set
bit 8 = 0 means alarm cleared
bit 7-1 is alarm category
0 = not used
1 = Personal safety
2 = Equipment safety
3 = Parameter control warning
4 = Parameter control error
5 = Irrecoverable error
6 = Equipment status warning
7 = Attention flags
8 = Data integrity
>8 = Other categories
9 - 63 reserved
used in: S5F1, S5F6, S5F8
ALED - Alarm enable/disable code
Format: B[1]
bit 8 = 1 means enable alarm
bit 8 = 0 means disable alarm
used in: S5F2, S5F4
ALID - Alarm identification
Format: U4
used in: S5F1 S5F2 S5F5, S5F6, S5F8, S5F71, S5F73
ALPY - Alarm priority
Format: U1
used in: S5F71
ALTX - Alarm text
Format: A[40]
used in: S5F1 S5F6, S5F8
Angle - Angle
Format: F8
Angles are measured counterclockwise from the positive X-axis to the positive Y-axis
Units are 1/100 degree.
used in : PLACEINFOREVx
SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02
HOST Interface Manual
Page 60 of 243 ©Siemens AG, all rights reserved
ASER - Alarm serial number
Format: U4
used in: S5F71
ASTAT - Alarm status
Format: Boolean
used in: S5F71, S5F73
CEED - Collection event enable/disable code
Format: B[1]
False = Disable
True = Enable
CEID - Collection event ID
Format: U4
used in: S2F35, S2F37, S6F3, S6F9, S6F11, S6F13, S6F15, S6F16, S6F17, S6F18
CLOCK - Clock YYYYMMDDhhmsscc
Format A[16]
used in: S5F71, S5F73, CLOCK, PICKUPDATARESETPOINT
closed_nozzle - Vacuum value for a nozzle
vacuum value measured with closed nozzle
Format: I4
Units are mbar
used in : VACUUMDATAREVx
ClusterName - Name of the actual cluster
Format: A
used in : TRACE_PCB_DATA
CMDA - Command acknowledge code
Format: B[1]
0 = completed or done
1 = command does not exist
2 = cannot perform now
>2 = other equipment specific error
3- 63 reserved
used in: S2F22, S2F28
CompLeft2Place Number of components which were not placed on the actual PCB
Format: I2
used in : GANTRYINFOx
CompPickedUp Number of components which were picked up successfully per
Gantry or Segment since the current PCB reached the center
conveyor.