00193368-02 - 第62页
SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02 HOST Inter fac e Manual Page 62 of 243 ©Siemens AG, all rights reser ved cubic_nozzle - Vacuum value f or a nozzle threshold f or cubic com ponents Format: …

SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02
HOST Interface Manual
©Siemens AG, all rights reserved page 61 of 243
Format: I2
used in : GANTRYINFOx, SEGMENTINFOREVx
CompPlaced Number of components which were placed per gantry or segment
since the current PCB reached the center conveyor.
Format:I2
used in : GANTRYINFOx, SEGMENTINFOREVx
CompChanged new tape / componentcontainer was added during placement
Format:U2
used in: TRACE_ALL_COMPONENTS
CompContainerSize amount of components in the container
In this version CompContainerSize is always = 0
Format:U4
used in: TAPE_INFO
CompBarcode(x) - Barcode of a component
Format: A
Used in : TRACE_ALL_COMPONENTS, TAPE_INFO
ComponentName - Name of a component
Format: A
used in: PLACEINFOREVx, PICKUPINFOREVx, TRACE_ALL_COMPONENTS
CoplanarityErrors
Not used ( = 0)
This value is part of PICKUPERRORSLOCx to be compliant to previous versions
Format: U2
CPACK - Command Parameter Acknowledge Code
Format: B[1]
1 = Parameter Name does not exist
2 = Illegal value specified for CPVAL
3 = Illegal format specified for CPVAL
4 = PP not in library
>4 = other equipment specific error
4- 63 reserved
used in: S2F22, S2F28
CPNAME - Command Parameter Name
Format: A
used in: S2F41, S2F42
CPVAL - Command Parameter Value
Format:
used in: S2F41

SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02
HOST Interface Manual
Page 62 of 243 ©Siemens AG, all rights reserved
cubic_nozzle - Vacuum value for a nozzle
threshold for cubic components
Format: I4
Units are mbar
used in : VACUUMDATEREVx
DATAID - Data ID
Format:
used in: S2F33, S2F35, S2F39, S2F49, S6F3, S6F5, S6F9, S6F11, S6F13, S6F13,
S6F16, S6F18
DATALENGTH - Data Length
Format: U4
used in: S2F39, S6F5
DataValid
The fields following the item „DataValid“ represent the result of optical centering. All fields
are not necessarily valid for all package forms. Verify the validity of a field using the
„DataValid“ byte and refer to the corresponding flag for the appropriate field.
If a bit is equal '1' the corresponding field is valid.
Bit 1 X-dev, Y-dev. and angle
Bit 2 Length and Width
Bit 3 lead count
Bit 4 Pitch
Bit 5 Orthogonal deviation
Bit 6 max. lead deviation
Bit 7 max. ball deviation
Example:
Data Valid = 39 (decimal) corresponds to a binary value of 0100111. This means
'X-dev, Y-dev. and angle', 'Length and Width', 'lead count' and 'max. lead deviation'
are valid.
Format: U2
Used in PLACEINFOREVx, PLACEINFOREVxSUB1
Division - Division at a feeder or the smallest partition in the tray of a Matrix Tray
Changer
Format: I2
used in: PICKUPINFOx
DRACK - Define Report Acknowledge Code
Format: B[1]
0 = Accept
1 = Denied. Insufficient space
2 = Denied. Invalid format

SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02
HOST Interface Manual
©Siemens AG, all rights reserved page 63 of 243
3 = Denied. At least one RPTID already defined
4 = Denied. At least one VID does not exist
>4 = Other errors
5 - 63 reserved
used in: S2F34
DSPER Data Sample Period
Format: A
used in: S2F23
EAC - Equipment Acknowledge Code
Format: B[1]
0 = Accept
1 = Denied. At least one constant does not exist
2 = Denied. Busy
3 = Denied. At least one constant out of range
>3 = Other errors
4 - 63 reserved
used in: S2F16
ECDEF - Equipment Constant Default Value
Format:
used in: S2F30
ECMAX - Equipment Constant MaximumValue
Format:
used in: S2F30
ECMIN - Equipment Constant Minimum Value
Format:
used in: S2F30
ECNAME - Equipment Constant Name
Format:
used in: S2F30
ERACK - Enable/Disable Event Report
Format: B[1]
0 = Accept
1 = Denied. At least one CEID does not exist
>1 = Other errors
2 - 63 reserved
used in: S2F38
Errorcode result of writing traceability data (bitcoded)
Traceability data are only reliable if errorcode is = 1
Format: U1
DEFAULT ERROR 0