00193368-02 - 第63页
SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02 HOST Inter fac e Manual ©Siemens AG, all rights reser ved page 63 of 243 3 = Denied. At least one RPTID already defined 4 = Denied. At least one VID does not…

SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02
HOST Interface Manual
Page 62 of 243 ©Siemens AG, all rights reserved
cubic_nozzle - Vacuum value for a nozzle
threshold for cubic components
Format: I4
Units are mbar
used in : VACUUMDATEREVx
DATAID - Data ID
Format:
used in: S2F33, S2F35, S2F39, S2F49, S6F3, S6F5, S6F9, S6F11, S6F13, S6F13,
S6F16, S6F18
DATALENGTH - Data Length
Format: U4
used in: S2F39, S6F5
DataValid
The fields following the item „DataValid“ represent the result of optical centering. All fields
are not necessarily valid for all package forms. Verify the validity of a field using the
„DataValid“ byte and refer to the corresponding flag for the appropriate field.
If a bit is equal '1' the corresponding field is valid.
Bit 1 X-dev, Y-dev. and angle
Bit 2 Length and Width
Bit 3 lead count
Bit 4 Pitch
Bit 5 Orthogonal deviation
Bit 6 max. lead deviation
Bit 7 max. ball deviation
Example:
Data Valid = 39 (decimal) corresponds to a binary value of 0100111. This means
'X-dev, Y-dev. and angle', 'Length and Width', 'lead count' and 'max. lead deviation'
are valid.
Format: U2
Used in PLACEINFOREVx, PLACEINFOREVxSUB1
Division - Division at a feeder or the smallest partition in the tray of a Matrix Tray
Changer
Format: I2
used in: PICKUPINFOx
DRACK - Define Report Acknowledge Code
Format: B[1]
0 = Accept
1 = Denied. Insufficient space
2 = Denied. Invalid format

SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02
HOST Interface Manual
©Siemens AG, all rights reserved page 63 of 243
3 = Denied. At least one RPTID already defined
4 = Denied. At least one VID does not exist
>4 = Other errors
5 - 63 reserved
used in: S2F34
DSPER Data Sample Period
Format: A
used in: S2F23
EAC - Equipment Acknowledge Code
Format: B[1]
0 = Accept
1 = Denied. At least one constant does not exist
2 = Denied. Busy
3 = Denied. At least one constant out of range
>3 = Other errors
4 - 63 reserved
used in: S2F16
ECDEF - Equipment Constant Default Value
Format:
used in: S2F30
ECMAX - Equipment Constant MaximumValue
Format:
used in: S2F30
ECMIN - Equipment Constant Minimum Value
Format:
used in: S2F30
ECNAME - Equipment Constant Name
Format:
used in: S2F30
ERACK - Enable/Disable Event Report
Format: B[1]
0 = Accept
1 = Denied. At least one CEID does not exist
>1 = Other errors
2 - 63 reserved
used in: S2F38
Errorcode result of writing traceability data (bitcoded)
Traceability data are only reliable if errorcode is = 1
Format: U1
DEFAULT ERROR 0

SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02
HOST Interface Manual
Page 64 of 243 ©Siemens AG, all rights reserved
FINISHED 1 (Traceability data are OK)
DUPLICATE PCB IN PROCESS 2
BARCODE DOUBLET 4
INPROCESSIBLE USER ACTION 8
TRACEABILTY ON DURING PROCESS 16
TRACEABILTY OFF DURING PROCESS 32
CANCELLED 64
DATA_LOST 128
ORPHAN 256
used in : TRACE_PCB_DATA
FCNID - Function Identification
Format: U1
used in: S2F43, S2F44
FeederAccessesPerPCB – Number of feeder accesses per PCB
Format: U2
used in: PICKUPERRORSLOCx
FeederType - Identifier for a feeder
Format: U2
1 Linear 4.5 mm
2 Linear 9.5 mm
3 Linear 10 mm
4 Linear 14 mm
5 Linear 30 mm
6 0402_0603
7 8 mm tape, electric, 2 x cycle
8 8 mm tape, electric
9 8 mm tape, mechanical, 2 x cycle
10 8 mm tape, mechanical
11 12mm tape "long"
12 16mm tape "long"
14 24mm "Blister" tape
15 32mm "Paper" tape
16 32mm "Blister" tape
17 44mm tape
18 56mm tape
19 8mm tape "long" 4mm manual
29 8mm tape "long" 2mm manual
30 waffle-pack tray, Matrix Tray Changer
56 24mm type III
57 32mm type III
58 44mm type III
59 56mm type III
60 S_G_12_S
61 S_G_16_S
62 S_G_24_S
63 S_G_32_S