00193368-02 - 第65页

SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02 HOST Inter fac e Manual ©Siemens AG, all rights reser ved page 65 of 243 64 S_G _44_S 65 S_G _56_S 66 72m m - S tape 79 3x8 m m tape 80 8mm Sur ftape f eeder…

100%1 / 243
SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02
HOST Interface Manual
Page 64 of 243 ©Siemens AG, all rights reserved
FINISHED 1 (Traceability data are OK)
DUPLICATE PCB IN PROCESS 2
BARCODE DOUBLET 4
INPROCESSIBLE USER ACTION 8
TRACEABILTY ON DURING PROCESS 16
TRACEABILTY OFF DURING PROCESS 32
CANCELLED 64
DATA_LOST 128
ORPHAN 256
used in : TRACE_PCB_DATA
FCNID - Function Identification
Format: U1
used in: S2F43, S2F44
FeederAccessesPerPCB – Number of feeder accesses per PCB
Format: U2
used in: PICKUPERRORSLOCx
FeederType - Identifier for a feeder
Format: U2
1 Linear 4.5 mm
2 Linear 9.5 mm
3 Linear 10 mm
4 Linear 14 mm
5 Linear 30 mm
6 0402_0603
7 8 mm tape, electric, 2 x cycle
8 8 mm tape, electric
9 8 mm tape, mechanical, 2 x cycle
10 8 mm tape, mechanical
11 12mm tape "long"
12 16mm tape "long"
14 24mm "Blister" tape
15 32mm "Paper" tape
16 32mm "Blister" tape
17 44mm tape
18 56mm tape
19 8mm tape "long" 4mm manual
29 8mm tape "long" 2mm manual
30 waffle-pack tray, Matrix Tray Changer
56 24mm type III
57 32mm type III
58 44mm type III
59 56mm type III
60 S_G_12_S
61 S_G_16_S
62 S_G_24_S
63 S_G_32_S
SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02
HOST Interface Manual
©Siemens AG, all rights reserved page 65 of 243
64 S_G_44_S
65 S_G_56_S
66 72mm-S tape
79 3x8 mm tape
80 8mm Surftape feeder
81 12mm Surftape feeder
82 24mm Surftape feeder
149 8mm tape „long“ 8mm
150 8mm "Schulz" tape
151 Fimecore
152 Nitto
153 Bulk-Case feeder
used in: PICKUPINFOREVx
FiducialName - Identifier of a fiduvial
Format: U2
used in: FIDUCIALDATA
Filling_level - Number of components in a division of a matrix tray changer
Format: I4
used in: MTCInfo
FillingLevel - unused always 0
Format U4
used in: TAPE_INFO
ForceIndex - programmed placement force
see chapter 3.5 in the SIPLACE Data Interface for a detailed description.
Format: U1
used in: PLACEINFOREVx
GANTRYGROUPID – ID of the gantry-group
Format: U2
1 = First gantrygroup in direction of transport
2 = Second gantrygroup in direction of transport
GANTRYID – ID of the gantry
Format: U2
1...4 (see charpter 'Machine Areas')
GRANT6 - Permission to send
Format: B[1]
0 = Permission granted
1 = Busy, try again
2 = Not interested
>2 = Other errors
3 - 63 reserved
SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02
HOST Interface Manual
Page 66 of 243 ©Siemens AG, all rights reserved
used in: S6F6
HCACK - Host Command Parameter Acknowledge Code
Format: B[1]
0 = Accept, Command has been performed
1 = Command does not exist
2 = Cannot perform now
3 = At least one parameter is invalid
4 = Acknowledge, command will be performed with completion signaled later by an
event
5 = Rejected. Already in desired condition
6 = control state is not remote
7 = recipe not in library
8 = control mode is not „GEM-Host“
9 = bad PP-Body
10 - 63 reserved
used in: S2F42
HEADID – ID of the head within a gantry
Format: U2
In this version there is only 1 head per gantry. HEADID is always = 1.
HEIGHTOFREVOLVER - distance between the head and the transport conveyor
During the reference run, the SIPLACE machines measures the difference between the
upper edge of the transport conveyor and the nozzle on segment 1. The
HEIGHTREVOLVER is then calculated by subtracting the length of the nozzle on segment
1 form the measured value. The nozzle length is defined in the machine data. So
HEIGHTREVOLOR is a relative, not an absolute value.
Format:I4
Units are 1/1000 mm
used in : HEIGHTREVOLVERx
JobName Name of the actual job
Format:A
used in: TRACE_PCB_DATA
LeadCount - Number of lead found during package form measurement
Format: U2
used in: PLACEINFOREVx
Length - Length of a package form
Length is returned from the vision system. It’s the „optical“ length of the package form.
Units are 1/1000 mm
Format: U4
used in: PLACEINFOREVx