00193368-02 - 第71页
SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02 HOST Inter fac e Manual ©Siemens AG, all rights reser ved page 71 of 243 used in : SEGMENT INFO REVx PlacementResult - Result of the placem ent action Format…

SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02
HOST Interface Manual
Page 70 of 243 ©Siemens AG, all rights reserved
used in: PLACEINFOREVx
PCBBarcode Barcode of the current PCB
Format: A
used in : TRACE_PCB_DATA
PickErrors - Number of pickup errors per segment since the current PCB reached the
center conveyor.
Format:I2
used in : SEGMENTINFOREVx
PickUpErrors - Number of pick-up errors since last download of a process program
Format: U2
used in: PICKUPERRORSLOCx
PickUpResult - Result of the pick up action
Format : U1
0 NOK (default value)
1 OK
2 NOK
used in : PLACEINFOREVx
PickUpVaccum - Vaccum measured at pick-up position.
PickUpVacuum is measured in the pick up circuit after a component is picked up
Format : I4
Units are mbar
used in : PICKUPINFOREVx
Pitch_per_lead_group - Distance between leads.
During the optical centering of a package the vision system calculate the average
distance between the leads within a lead group.
Format: I4
used in : PLACEINFOREVx
PLACEERRORDESCRIPTION – Description of an placement error.
Format : U2
2 : Visionerror
3 : Vacuumerror
4: ComponentSensor - empty Nozzle
5: ComponentSensor - occupied Nozzle
In case of errors 2 and 3 at the same time, a visionerror (2) will be reported
PlaceErrors - Number of place errors per segment since the current PCB reached the
center conveyor.
Format:I2

SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02
HOST Interface Manual
©Siemens AG, all rights reserved page 71 of 243
used in : SEGMENTINFOREVx
PlacementResult - Result of the placement action
Format : U1
1 : Component placed
2 : Component was thrown away, because of an detected error
used in : PLACEINFOREVx
PlacementVaccum - Vacuum measured during placement.
Format : I4
PlacementVacuum is measured in the placement circuit before the component is placed.
UNITS are mbar
used in : PLACEINFOREVx
PPBODY - Process Program Body
Format: A
used in: S7F3, S7F6
PPGNT - Process Program Grant
Format: B[1]
0=OK
1 = already have
2 = no space
3 = invalid PPID
4 = busy, try later
5 = will not accept
>5 other error
6 - 63 reserved
used in: S7F2
PPID - Process Program ID
Format: A[8]
used in: S2F27, S7F1, S7F3, S7F5, S7F6, S7F17, S7F20
PRTID - Report ID
Format: U4
used in: S2F33, S2F35, S6F3, S6F9, S6F11, S6F13, S5F16, S6F18, S6F19, S6F21
ProdTimeStart Time of production start
Format: A
used in : TRACE_PCB_DATA
ProdTimeEnd Time of production end
Format: A
used in : TRACE_PCB_DATA
Quality - Measurement result of a package form or a fiducial

SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02
HOST Interface Manual
Page 72 of 243 ©Siemens AG, all rights reserved
Quality ranges between 0 and 100. The higher the value, the better the fiducial was
recognized.
Format: U1
used in: PLACEINFOREVx, FIDUCIALDATA
RCMD - Remote Command
Format: A
used in: SsF21, S2F41
RealNozzleLength - measured nozzle length
The nozzle length is measured during the reference run. It depends on the
HEIGHTREVOLER value. So REAL_NOZZLE_LENGTH is not a absolute but a relative
value.
It is calculated by subtracting the measured difference between the nozzle and the upper
edge of the conveyor belt from the HEIGHTREVOLER value.
Format: I4
Units are 1/1000 mm
Reference - Referencenumber of a componentbatch
One reference used in TRACE_SINGLE_CIRCUIT points to one component in
TRACE_ALL_COMPONENTS.
Format: U4
ReferenceDesignator - Identifier for a placement position
Format: A
see chapter 5.4 in the SIPLACE Data Interface ( <position_name> in
<placemant_pos_record>).
used in: PLACEINFOREVx
REPGSZ - Reporting group size
Format: U4
used in: S2F23
RSDA - Request Spool Data Acknowledge
Format: B[1]
0=OK
1 = Denied, busy try later
2 = Denied, spooled data does not exist
3 - 63 reserved
used in: S2F24
RSDC Request Spool Data Code
Format: B[1]
0 = Transmit Spooled Massages
1 = Purge Spooled Messages
2 - 63 reserved
SAFE_SPOOL_MODE (EC)