00193368-02 - 第72页
SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02 HOST Inter fac e Manual Page 72 of 243 ©Siemens AG, all rights reser ved Quality ranges between 0 and 100. The higher the value, the better the f iducial wa…

SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02
HOST Interface Manual
©Siemens AG, all rights reserved page 71 of 243
used in : SEGMENTINFOREVx
PlacementResult - Result of the placement action
Format : U1
1 : Component placed
2 : Component was thrown away, because of an detected error
used in : PLACEINFOREVx
PlacementVaccum - Vacuum measured during placement.
Format : I4
PlacementVacuum is measured in the placement circuit before the component is placed.
UNITS are mbar
used in : PLACEINFOREVx
PPBODY - Process Program Body
Format: A
used in: S7F3, S7F6
PPGNT - Process Program Grant
Format: B[1]
0=OK
1 = already have
2 = no space
3 = invalid PPID
4 = busy, try later
5 = will not accept
>5 other error
6 - 63 reserved
used in: S7F2
PPID - Process Program ID
Format: A[8]
used in: S2F27, S7F1, S7F3, S7F5, S7F6, S7F17, S7F20
PRTID - Report ID
Format: U4
used in: S2F33, S2F35, S6F3, S6F9, S6F11, S6F13, S5F16, S6F18, S6F19, S6F21
ProdTimeStart Time of production start
Format: A
used in : TRACE_PCB_DATA
ProdTimeEnd Time of production end
Format: A
used in : TRACE_PCB_DATA
Quality - Measurement result of a package form or a fiducial

SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02
HOST Interface Manual
Page 72 of 243 ©Siemens AG, all rights reserved
Quality ranges between 0 and 100. The higher the value, the better the fiducial was
recognized.
Format: U1
used in: PLACEINFOREVx, FIDUCIALDATA
RCMD - Remote Command
Format: A
used in: SsF21, S2F41
RealNozzleLength - measured nozzle length
The nozzle length is measured during the reference run. It depends on the
HEIGHTREVOLER value. So REAL_NOZZLE_LENGTH is not a absolute but a relative
value.
It is calculated by subtracting the measured difference between the nozzle and the upper
edge of the conveyor belt from the HEIGHTREVOLER value.
Format: I4
Units are 1/1000 mm
Reference - Referencenumber of a componentbatch
One reference used in TRACE_SINGLE_CIRCUIT points to one component in
TRACE_ALL_COMPONENTS.
Format: U4
ReferenceDesignator - Identifier for a placement position
Format: A
see chapter 5.4 in the SIPLACE Data Interface ( <position_name> in
<placemant_pos_record>).
used in: PLACEINFOREVx
REPGSZ - Reporting group size
Format: U4
used in: S2F23
RSDA - Request Spool Data Acknowledge
Format: B[1]
0=OK
1 = Denied, busy try later
2 = Denied, spooled data does not exist
3 - 63 reserved
used in: S2F24
RSDC Request Spool Data Code
Format: B[1]
0 = Transmit Spooled Massages
1 = Purge Spooled Messages
2 - 63 reserved
SAFE_SPOOL_MODE (EC)

SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02
HOST Interface Manual
©Siemens AG, all rights reserved page 73 of 243
0 = SAFE_SPOOL_MODE is not activ (no SafeSpool-Stop)
1 = SAFE_SPOOL_MODE is activ, SafeSpool-Stop after MAX_TIME_TO_STOP Minutes
of spooling
SEGMENT – Number of the segment to pick up or place a component.
Format: U1
Setup Name of the current Setup
Format: A
used in : TRACE_PCB_DATA
SHEAD - Stored header related to the transaction timer
Format: B[10]
used in: S9F9
SingleCircuitName - Name of a singlecircuit on a pcb
Format: A
used in: TRACE_SINGLE_CIRCUIT
SMPLN - Sample number
Format : U4
used in: S6F1
SOFTREV - Software revision code
Format: A[6]
used in: S1F2, S1F13, S1F14, S1F65, S1F66
STIME - Sample time
Format: A[16]
used in: S6F1
STRACK - Spool Stream Acknowledge
Format: B[1]
1 = Spooling not allowed for stream
2 = Stream unknown
3 = Unknown function specified for this stream
4 = Secondary function specified for this stream
used in: S6F44
STRID - Stream ID
Format: U1
used in: S2F43, S2F44
SVID - Status Variable ID
Format
used in: S2F23
SVNAME - Status variable name
Format: A