SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02 HOST Inter fac e Manual ©Siemens AG, all rights reser ved page 73 of 243 0 = SAFE_SPOOL_MO DE is not activ ( no SafeSpool- Stop) 1 = SAFE_SPOOL_MO DE is acti…

SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02
HOST Interface Manual
Page 72 of 243 ©Siemens AG, all rights reserved
Quality ranges between 0 and 100. The higher the value, the better the fiducial was
recognized.
Format: U1
used in: PLACEINFOREVx, FIDUCIALDATA
RCMD - Remote Command
Format: A
used in: SsF21, S2F41
RealNozzleLength - measured nozzle length
The nozzle length is measured during the reference run. It depends on the
HEIGHTREVOLER value. So REAL_NOZZLE_LENGTH is not a absolute but a relative
value.
It is calculated by subtracting the measured difference between the nozzle and the upper
edge of the conveyor belt from the HEIGHTREVOLER value.
Format: I4
Units are 1/1000 mm
Reference - Referencenumber of a componentbatch
One reference used in TRACE_SINGLE_CIRCUIT points to one component in
TRACE_ALL_COMPONENTS.
Format: U4
ReferenceDesignator - Identifier for a placement position
Format: A
see chapter 5.4 in the SIPLACE Data Interface ( <position_name> in
<placemant_pos_record>).
used in: PLACEINFOREVx
REPGSZ - Reporting group size
Format: U4
used in: S2F23
RSDA - Request Spool Data Acknowledge
Format: B[1]
0=OK
1 = Denied, busy try later
2 = Denied, spooled data does not exist
3 - 63 reserved
used in: S2F24
RSDC Request Spool Data Code
Format: B[1]
0 = Transmit Spooled Massages
1 = Purge Spooled Messages
2 - 63 reserved
SAFE_SPOOL_MODE (EC)

SIPLACE GEM for S25HM, S27HM, HS50, HS60 SW Version GEM 503.02
HOST Interface Manual
©Siemens AG, all rights reserved page 73 of 243
0 = SAFE_SPOOL_MODE is not activ (no SafeSpool-Stop)
1 = SAFE_SPOOL_MODE is activ, SafeSpool-Stop after MAX_TIME_TO_STOP Minutes
of spooling
SEGMENT – Number of the segment to pick up or place a component.
Format: U1
Setup Name of the current Setup
Format: A
used in : TRACE_PCB_DATA
SHEAD - Stored header related to the transaction timer
Format: B[10]
used in: S9F9
SingleCircuitName - Name of a singlecircuit on a pcb
Format: A
used in: TRACE_SINGLE_CIRCUIT
SMPLN - Sample number
Format : U4
used in: S6F1
SOFTREV - Software revision code
Format: A[6]
used in: S1F2, S1F13, S1F14, S1F65, S1F66
STIME - Sample time
Format: A[16]
used in: S6F1
STRACK - Spool Stream Acknowledge
Format: B[1]
1 = Spooling not allowed for stream
2 = Stream unknown
3 = Unknown function specified for this stream
4 = Secondary function specified for this stream
used in: S6F44
STRID - Stream ID
Format: U1
used in: S2F43, S2F44
SVID - Status Variable ID
Format
used in: S2F23
SVNAME - Status variable name
Format: A

SIPLACE GEM for S25HM, S27HM, HS50 , HS60 SW Version GEM 503.02
HOST Interface Manual
Page 74 of 243 ©Siemens AG, all rights reserved
used in: S1F12
Table Barcode - Barcode of a table
Format: A
used in: Table _ID
TEXT - A single line of characters
Format: A[160]
used in: S10F1, S10F3, S10F5, S10F9
TIAACK - Equipment Acknowledge Code
Format: B[1]
0 = everything correct
1 = too many SVIDs
2 = no more traces allowed
3 = invalid period
4 - 63 reserved
used in; S2F24
TIACK - Time Acknowledge Code
Format: B[1]
0=OK
1 = Error, not done
2 - 63 reserved
used in; S2F32
TID - Terminal ID
Format: B[1]
0 = single or main terminal
>0 = additional terminals on same equipment
used in: S10F1, S10F3, S10F5
TOTSMP - Total sample to be made
Format: U4
used in: S2F23
TrackNumber - Number of a track
Format: I2
used in: PICKUPINFO1REVx, PICKUPERRORSLOCx
tol_dirty_nozzle - vacuum value
Format: I4
Units are mbar
used in : VACUUMDATEREVx
tol_leaky_nozzle - vacuum value
Format: I4
Units are mbar
used in : VACUUMDATEREVx