00194579-0202 - 第49页

Retrofit instructions Wide board 242 / 508 mm SIPLACE HS-60 / D4 08/2006 Edition 51 : Us e the "PCB conveyor", "Options and configuration", "T each" function to move the stationar y conveyor…

100%1 / 62
Retrofit instructions Wide board 242 / 508 mm SIPLACE HS-60 / D4
08/2006 Edition
50
: Release the clamp on the stationary side using the grub screw.
Remember to tighten the grub screw once more after changing the conveyor width.
2
2
: Switch to service engineer mode in SITEST.
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Grub screw
clamp
Retrofit instructions Wide board 242 / 508 mm SIPLACE HS-60 / D4
08/2006 Edition
51
: Use the "PCB conveyor", "Options and configuration", "Teach" function to move the stationary
conveyor side wall 5 x 10 mm increments to the side so that you can remove the assembly tray
limit switch from its current position.
2
Do not accept the setting. Do not click on OK. 2
2
2
2
2
Limit switch,
old version
Retrofit instructions Wide board 242 / 508 mm SIPLACE HS-60 / D4
08/2006 Edition
52
: Fit the limit switch on the new mount and then on the bearing flange of the conveyor side wall.
2
2
: Move the stationary conveyor side wall 5 x 10 mm increments to the original position.
2
Do not accept the setting. 2
2
2
2
2
2
Assembly tray limit
switch new position