00194579-0202 - 第60页
Retrofit instructions Wide board 242 / 508 mm SIPLACE HS-60 / D4 08/2006 Edition 62
Retrofit instructions Wide board 242 / 508 mm SIPLACE HS-60 / D4
08/2006 Edition
61
2.9 Error scenarios
2.9.1 Error scenario: The machine zero point is moved without subsequently
"reducing / increasing the minimum traveling range for gantry 3“ and "cali-
brating the machine after moving the machine zero point“
After the machine zero point is moved, if the minimum traveling range is not modified and the ma-
chine is not then calibrated, then the machine will not run. 2
2.9.2 Error scenario: The extended conveyor configuration "Wide ...“ is set wit-
hout subsequent calibration
If no LP mapping is carried out after the extended conveyor configuration "Wide HS-60“ is set for
the first time, then the placement area thus obtained cannot be mapped. 2
After the extended conveyor configuration has been changed, if the conveyor is not calibrated,
then various problems may occur when setting minimum / maximum conveyor widths. This can
also affect other performance features, such as the "Flexible dual conveyor“ performance fea-
ture. 2
2.9.3 Error scenario: The wrong conveyor type is used
The operator is responsible for ensuring that only standard feeders are used. No such checks are
carried out by the station. If this is ignored, it can cause problems during placement which require
the machine to be switched off. 2
2
2
2
Retrofit instructions Wide board 242 / 508 mm SIPLACE HS-60 / D4
08/2006 Edition
62