TR7600 SIII_Hardware_en_v_2_0_4 - 第23页

Test Research, Inc . TR7600 SIII Seri es User Gu ide – Hardw are 13 : Use the board holder equipment to clip the tested board. : Use the board holder equipment to release the tested board. : Lock the front and back doo r…

100%1 / 65
Test Research, Inc.
12 TR7600 SIII Series User Guide – Hardware
3.4 Control
In the [Control] menu, you can set up or test for light, conveyor, and gates.
Figure 15: VPLC/ Control
: Click this button to test if the red light can work correctly.
: Click this button to test if the yellow light can work correctly.
: Click this button to test if the green light can work correctly.
: Activate the alarm buzzer that will sound to warn operators if the Unloader is not
ready to avoid causing a board blockage at the Loader.
Test Research, Inc.
TR7600 SIII Series User Guide – Hardware 13
: Use the board holder equipment to clip the tested board.
: Use the board holder equipment to release the tested board.
: Lock the front and back doors.
: Make the Stop Pin stretch out. This function is not applied to TR7600LL SIII,
TR7600XLL SII, TR7600LL SII, TR7680 and TR7600M SII. This function is only used in
some specific types of machines that have a Stop Pin.
: Open the left gate.
: Open the right gate.
: Close the left gate.
: Close the right gate.
Test Research, Inc.
14 TR7600 SIII Series User Guide – Hardware
3.5 Settings
Figure 16: VPLC/ Settings
In-line
Loader: Enable this function and the machine will open the front door only after the
machine has received the [Board Is Ready] signal from the upstream.
Unloader: Tick [Unloader] if there is an unloader. In the [Inline] mode, once a test is
completed and the unloader sends a READY signal, the board will be unloaded
automatically. If there is no loader, once the test is completed, the board will stop at the
exit and wait for manual removal before the machine processes the next board-in.
By Pass: If the system is malfunctioning or testing is not desired, click [Yes] and then the
board will not be tested and goes straight to the unloader.
Sync. In & Out: If the machine finishes the inspection, it sends the tested board out of the
machine and imports the next board into the machine simultaneously.
Buzzer: Tick [Buzzer] to activate the alarm buzzer that will sound if the unloader is not
ready and causes a board blockage at the loader.