Fitting the Vacuum Pump Changeover 3.2.5 Prefitting the Vacuum Pump 92 Vacuum Pump Vakuumpumpe 3.2.5 3 . 2 . 5 P r e f it t in g t h e V a c u u m P u m p Prefitting the Vacuum Pump Before the pump can b e fitted, it nee…

100%1 / 132
Fitting the Vacuum Pump
3.2.4 Converting the Gantries Changeover
Vacuum Pump Vakuumpumpe 91
3.2.4.2
3.2.4.2 Connecting Transparent Hoses
Connecting Transparent Hoses
Standard gantry
Rotated gantry
Fasten the duo tube connection using two M3x35 mm
screws (1).
Connect the two transparent hoses to the
connection (2).
Run the two transparent hoses to the trailing cable.
Use adhesive to attach a cable clamp (3). Fix the
transparent hoses to the cable clamp with a cable tie.
Make sure that you do not restrict the hose width with
the cable tie.
Run the hoses next to the guide plate and
upwards (4).
There may be differences here, due to the different
variants of the gantry trailing cable.
NOTICE!
Use cable ties to fasten the hoses where necessary.
Make sure that you do not restrict the hose width with the
cable tie.
Connect the two transparent hoses to the
connection (5).
Fitting the Vacuum Pump
Changeover 3.2.5 Prefitting the Vacuum Pump
92 Vacuum Pump Vakuumpumpe
3.2.5
3.2.5 Prefitting the Vacuum Pump
Prefitting the Vacuum Pump
Before the pump can be fitted, it needs to be prepared. This preparation work covers the following tasks:
"3.2.5.1 Closing the Opening Mechanism" [ 92]
"3.2.5.2 Connecting the Power cable" [ ➙ 93]
"3.2.5.3 Fitting and Positioning the Filter" [ ➙ 94]
"3.2.5.4 Preparing the Distributor Block" [ 96]
Vacuum pump in original state
3.2.5.1
3.2.5.1 Closing the Opening Mechanism
Closing the Opening Mechanism
CAUTION
Lifting the vacuum pump
When lifting the vacuum pump, always take hold of its base. As its center of gravity is above
this base, parts of the pump could be pulled off if you take hold of it elsewhere.
Never lift the vacuum pump by its front plate! The front plate of the vacuum pump is only
fixed with rubber buffers. Take care not to damage the rubber buffers.
1. Cover on electricity connection box
2. Leakage valve
3. Opening mechanism
4. Eyelet (only in pumps for SX1/SX2 and DX1/DX2 ma-
chines
5. Front plate
If necessary, replace the eyelet (4) with a screw
ISO4762-M 10x25-A2-70 [03042599-xx]
NOTICE
Clean the parts if necessary
If the vacuum pump has previously been fitted in a machine, clean it before fitting all vacu-
um-conducting parts to remove any existing contaminants e.g. Loctite residues.
1. Sealing plugs
2. Sealing ring
3. Opening mechanism
If not prefitted, position the sealing ring (2) on the
sealing screw (R3/4 St+NBR) [03004775-xx] (1) and
screw both into the opening on the top of the pump
(3).
If there is no sealing ring available, first apply Loctite
55 onto the threaded connection as a sealant.
Fitting the Vacuum Pump
3.2.5 Prefitting the Vacuum Pump Changeover
Vacuum Pump Vakuumpumpe 93
3.2.5.2
3.2.5.2 Connecting the Power cable
Connecting the Power cable
Screws 1 -4 on the cover
5. Strain relief
Remove the four screws (1) to (4) fastening the cover
on the electricity connection box and then remove the
cover.
Turn the strain relief out (5).
1. Power cable
2. Tension relief
Thread the power cable [03079997-xx] (1) through
the strain relief (2) and the sealing ring (3).
1. Power cable
2. Tension relief
Thread the power cable into the electricity connection
box (1) and turn the strain relief until tight (2).