00191376-07 - 第27页
HS Preventive Maintenance 4 W eekly maintenance jobs 01/2006 US Edition 27 Empty the component drawer or flap of the 8 mm S feeder 4 : Unplug the 8 m m S fee der and lift it o ff the change over table. 4 a Remove loose c…

4 Weekly maintenance jobs HS Preventive Maintenance
01/2006 US Edition
26
4

HS Preventive Maintenance 4 Weekly maintenance jobs
01/2006 US Edition
27
Empty the component drawer or flap of the 8 mm S feeder 4
: Unplug the 8 mm S feeder and lift it off the changeover table.
4
a Remove loose components from the changeover table with a brush or using the vacuum
cleaner.
4
s Empty the component drawer of the 2x8 mm S feeder (if present).
4
d Open the flap of the 3x8 mm S feeder (if present) and remove the components.
4
f Wipe the base of the feeder module to remove any dirt.
4
g Cut off the used tape so that it is flush with the feeder.
4
: Return the feeders to their original (correct) locations.
4
Make sure that the feeder is seated firmly on the changeover table and is inserted at the right po-
sition. 4
4
4
4
: Close the protective cover.
: Repeat these tasks in every placement area.
4
4
4
4

5 Monthly maintenance jobs HS Preventive Maintenance
01/2006 US Edition
28
5 Monthly maintenance jobs
5