00191376-07 - 第36页

6 2-monthly maintenance jobs HS Preventive Maintenance 01/2006 US E dition 36 6

100%1 / 86
HS Preventive Maintenance 6 2-monthly maintenance jobs
01/2006 US Edition
35
6
You will need the following tools, equipment and consumables for the 2-monthly maintenance. 6
Vacuum cleaner
Condensate catch tray
Short-bristled brush
Phillips screwdriver
Whetstone
–Scissors
Lint-free cloths
ISOFLEX TOPAS NCA52 grease
–WD40
Filter insert,
5 microm. for series 112, if required
New silencer for the Collect&Place head DLM1, HS-50, if required
New silencer for the Collect&Place head DLM2, HS-60, if required
6
6
Inspect or replace the filter cartridge 6
: Open the door to the compressed air supply.
: Place a catch tray beneath the compressed air maintenance unit.
a Close the main compressed air valve.
s Once both manometers read 0, switch the machine off at the main switch.
6
d Remove the cover flap by pulling the yellow cap release down and turning the cover flap
counter-clockwise (bayonet fitting).
6
6
6
6 2-monthly maintenance jobs HS Preventive Maintenance
01/2006 US Edition
36
6
HS Preventive Maintenance 6 2-monthly maintenance jobs
01/2006 US Edition
37
a Remove the condensate tank by turning it counter-clockwise and then pulling it down and out
(bayonet fitting).
s Unscrew the filter casing from the compressed air maintenance unit.
d Unscrew the Phillips screw to remove the filter from the filter casing.
f Replace the filter if it is dirty.
: Reverse the sequence described above to refit the filter and filter casing.
6
: Open the main compressed air valve once more.
6
6
Inspect or replace the silencer 6
: Check the silencer of the Collect&Place head for dirt.
If it appears discolored, turn the retainer counter-clockwise.
: Replace the dirty filter and reverse the sequence described above to fit.
6
6