a Remove the condensate tank by turning it counter-clockwise and then pulling it down and out
(bayonet fitting).
s Unscrew the filter casing from the compressed air maintenance unit.
d Unscrew the Phillips screw to remove the filter from the filter casing.
f Replace the filter if it is dirty.
: Reverse the sequence described above to refit the filter and filter casing.
6
: Open the main compressed air valve once more.
6
6
Inspect or replace the silencer 6
: Check the silencer of the Collect&Place head for dirt.
If it appears discolored, turn the retainer counter-clockwise.
: Replace the dirty filter and reverse the sequence described above to fit.
6
6
6
6
6
6
6
6
6
6
6
6
6
6

6 2-monthly maintenance jobs HS Preventive Maintenance