Check the protective covers 8
a Open the protective covers to a height of 100 mm (+/-5mm) measured between the machine
frame and the edge of the protective cover. Replace the damping cylinder if the damping cyl-
inder covers cannot be held open reliably at this height.
8
: Close the protective covers.
8
Clean the protective covers 8
: Check the Plexiglas surfaces of the protective covers for dirt.
: Clean them with a dry lint-free cloth if necessary.
If they are very dirty, moisten the cloth with ethyl alcohol.
8
Apply as little pressure as possible when cleaning the protective covers to avoid damaging the
ESD coating. 8
8
8
: Repeat these tasks at every placement machine of the line.
: Switch the placement system on again at the main switch.