OM-1078-002 - 第112页
*3 "Mode" Group Box V arious actions can be selected. The following buttons are provided in this group box. [All Beam (Incl. NC Axis) Heads Zero] Button When this button is pressed, all X/Y beams are zeroed. Wh…

• Sheet Composition
*1 Fdr. No. Tray Set
Set the feeder No. to be taught.
When the [Fdr. No.] button is pressed, the "Feeder No. Set" sheet
appears.
Refer to "5.3.6 "Feeder No. Set" Sheet" for details.
*2 "Select Option" Group Box
The following buttons are provided in this group box.
[Tray Zeroing Corner] Button
When this button is pressed, the teaching operation is preformed
on the tray zeroing corner.
The teaching operation is performed on the tray zeroing corner
through manual alignment to calculate the tray positional offsets ("X
(mm) and "Y (mm)") of "OFFSET" in the component data ("Tray
Steps Information").
[Pick-Up First Pos.] Button
When this button is pressed, the teaching operation is performed
on the position where the first component should be taken out from
the tray.
While the "SIDE LENGTH" parameters (X and Y) in "TRAY DATA"
are calculated, the first data for pitch calculation is extracted.
[Pick-Up Last Pos.] Button
When this button is pressed, the teaching operation is performed
on the position where the last component should be taken out from
the tray.
This function is used to extract the second data for pitch calcula-
tion. The "PITCH (CALC.)" parameters (X and Y) in the component
data are calculated in combination with the previously calculated
first data (takeout position).
0204-001 2-38
AHI01EGP
5.3 "TEACHING" Window (Submenu)

*3 "Mode" Group Box
Various actions can be selected.
The following buttons are provided in this group box.
[All Beam (Incl. NC Axis) Heads Zero] Button
When this button is pressed, all X/Y beams are zeroed.
When the [ENABLE] button on the operation panel is pressed in 2
seconds after this button and the [ON] button (entitled "MOVE"), the
zeroing operation starts.
[Data Pos. Move] Button
When this button is pressed, the X/Y beam moves to the specified
position.
When the [ENABLE] button is pressed on the operation panel in 2
seconds after this button and the [ON] button (entitled "MOVE"), the
X/Y beam moves to the position where the parameters set in the "X
(mm)" and "Y (mm)" data fields of the label "OFFSET" in the com-
ponent library data and the step data are referred to.
[Manual Alignment] Button
When the [MOVE] button is pressed after this button, the pointing
device operation becomes accessible and the manual alignment
operation can be performed.
[Manual Axis] Button
When this button is pressed, the "Manual Axis" sheet appears.
*4 Set Status
When the "P.E.C. Dsbl." or the "Comp. Recognition Dsbl." check
box in the "Test Run" tab sheet is turned on (checked), the back-
ground color of "Recognition Dsbl." turns light red. (No background
color in normal cases).
No recognition processing is made even if a teaching op-
eration is performed when each check box is turned on
(checked) in the "Test Run" tab sheet. Therefore, various
teaching operations will get incorrect results.
When all beams are zeroed completely, the background color of "All
Beam Zero" turns green. Otherwise, the background has no color.
(a) When each section is not set up and a teaching opera-
tion is performed, note that the offset values may not
be taught correctly.
(b) Before performing a teaching operation, be sure to zero
all beams.
0311-002 2-39
AHI01EGP
5.3 "TEACHING" Window (Submenu)
Note
Note

*5 [Tray Unit Adj.] Button
When this button is pressed, the "Tray Unit Adj." sheet appears.
*6 [Clear Adj.] Button
When this button is pressed, the following "Confirmation" dialog box
opens.
Fig. B25
*7 [Cancel] Button
When pressed, this button cancels the results of the teaching op-
eration without reflecting them on the offset data.
*8 [End] Button
When this button is pressed, the following "Confirmation" dialog box
opens.
Fig. B26
When the [YES] button is pressed, the results of the teaching op-
eration are reflected on the offset data and the dialog box closes.
When the [NO] button is pressed, the dialog box closes without re-
flecting the results of the teaching operation on the offset data.
*9 "Control Switch" Group Box
When the [ENABLE] button on the operation panel is pressed in 2
seconds after one of the buttons in the "Mode" group box (*3) and
the [ON] button (entitled "MOVE"), the selected action takes place.
*10 [Return] Button
When this button is pressed, the "Pick-Up Location" sheet appears.
0311-002 2-40
AHI01EGP
5.3 "TEACHING" Window (Submenu)