OM-1078-002 - 第141页
031 1-001 3-21 AHI01EGP

0311-002 3-20 AHI01EGP
Tray matrix reference setup
Select "Left" or "Right".
Tray matrix initialization mode
"Standard", "Hold", or "Initialize" can be selected.
Standard : When the same or no component IDs are speci-
fied in the tray matrix data of the current pattern
program after the program change operation, the
tray matrix data will be used continuously.
When different component IDs are specified after
the program change operation, the matrices (posi-
tional coordinates) will be cleared to (0,0).
Hold : When the same or no component IDs are speci-
fied in the tray matrix data of the current pattern
program after the program change operation, the
tray matrix data will be used continuously.
When different component IDs are specified after
the program change operation, the matrices (posi-
tional coordinates) will be cleared to (1, 1).
Initialize : All matrices (positional coordinates) in the current
tray matrix data will be cleared to (1, 1).
Tray tall component mode
"Enable" or "Disable" can be selected.
3.2 Auto Operation

031 1-001 3-21 AHI01EGP

Section 4
Maintenance and Troubleshooting
0311-002 4-1 AHI01EGP
This section describes periodic maintenance operations, etc.,
for those who are in charge of the machine maintenance.