OM-1078-002 - 第155页

Maintenance Spots Name DWG No. Elevator Shaft Belt D8 Inspection - Visual Inspection 1. 6 Y early Maintenance Fig. D8 Elevator Shaft 1.6 Y early Maintenance Description Grease Cleaning T ools, Nozzles, etc. Check T able …

100%1 / 223
When a pallet is warped, the component pickup rate
may deteriorate.
Fig. D7 Pallet
1.5 Maintenance (Every 3 Months)
0311-003 4-12 AHI01EGP
Rail
Inspection
Check if the lower areas of the pallet
rails are worn out or not, using a scale.
(Up to 0.5 mm or less)
Upper Surface
Inspection
Check the warpage of the pallet with a
scale.
(Up to 0.5 mm or less)
Note
Maintenance Spots
Name DWG No.
Elevator Shaft Belt D8 Inspection - Visual
Inspection
1.6 Yearly Maintenance
Fig. D8 Elevator Shaft
1.6 Yearly Maintenance
Description
Grease
Cleaning
Tools, Nozzles,
etc.
Check
Table D5
Belt
Inspection
Check to see if the belt is worn out or not.
0109-001 4-13 AHI01EGP
1.7 Detechment and Attachment of Covers
1.7 Detachment and Attachment of Covers
When the maintenance cover of the multi-layer tray
feeder is detached, the power to the loads is shut
off.
The multi-layer tray feeder cannot be operated with
the maintenance cover being detached.
1.7.1 Detachment of Covers
(1) Zero the multi-layer tray feeder.
(2) Manually lower the rack to the position (16th step) for easier lubrica-
tion work.
(3) Shut off the power.
(4) Remove two side setscrews with a cross-head screwdriver.
The side maintenance cover will come off.
(5) Remove two central setscrews with a cross-head screwdriver.
(6) Remove two central setscrews located inside the safety door with a
cross-head screwdriver. The central maintenance cover will come
off.
Fig. D9
0311-003 4-14 AHI01EGP
Side Maintenance Cover
Side Setscrews (2 places)
Central Setscrews (2 places)
(located inside the safety door)
Central Maintenance Cover
Central Setscrews (2 places)
CAUTION