OM-1078-002 - 第165页
Error ID Item Description 1 10201 T V # 1 Axis Timing 1 10301 T V # 1 Axis Data (Cause 1) Self-Diagnostics Error Message (Remedy 1) Zero all axes and re-start the operation. When the machine cannot be set to its normal c…

2.3.3 Error IDs and Controlled Areas
Error ID Item Description
110101 TV #1 Axis Origin Rack shutter not opened within specified time. (0101)
110102 TV #1 Axis Origin Pallet chuck not closed within specified time. (0102)
110103 TV #1 Axis Origin Operatiing condition for zeroing not fulfilled. (0103)
110104 TV #1 Axis Origin Pallet installation error detected; BPH504/505 (0201)
110105 TV #1 Axis Origin Pallet detected. (0202)
110106 TV #1 Axis Origin Operation not completed normally. (0203)
110107 TV #1 Axis Origin Zeroing not completed within specified time. (0204)
110108 TV #1 Axis Origin Pallet installation error detected.;BPH504/505 (0401)
110109 TV #1 Axis Origin Pallet detected. (0402)
11010a TV #1 Axis Origin Operation not completed normally. (0403)
11010b TV #1 Axis Origin Zeroing not completed within specified time. (0404)
11010c TV #1 Axis Origin Pallet detected. (0501)
11010d TV #1 Axis Origin Zeroing not completed within specified time. (0502)
11010e TV #1 Axis Origin Pallet installation error detected before destinatation.
(0601)
11010f TV #1 Axis Origin Pallet detected. (0701)
110110 TV #1 Axis Origin Operation not completed normally. (0702)
110111 TV #1 Axis Origin Zeroing not completed within specified time. (0703)
110112 TV #1 Axis Origin Rack shutter not closeed within specified time.
(0704)
110113 TV #1 Axis Origin Rack shutter not closeed within specified time.
(0801)
110114 TV #1 Axis Origin Origin detected after end of zeroing operation. (0901)
110115 TV #1 Axis Origin Origin detected after end of zeroing operation. (1001)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0109-001 4-19 AHI01EGP
2.3 Troubleshooting after "ERROR" Window (Error ID)

Error ID Item Description
110201 TV #1 Axis Timing
110301 TV #1 Axis Data
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
110401 TV #1 Axis Limit
110402 TV #1 Axis Limit
(Cause 1) The X1 axis might have overrun due to generation of noises, overcurrent, etc.
The sensor may be defective.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
110601 TV #1 Axis Interlock Driver Alarm
110602 TV #1 Axis Interlock Pick-Up Error Detection (Upper)
110603 TV #1 Axis Interlock Pick-Up Error Detection (Lower)
110604 TV #1 Axis Interlock Pass-line Interlock
110605 TV #1 Axis Interlock
110606 TV #1 Axis Interlock
110607 TV #1 Axis Interlock
110608 TV #1 Axis Interlock
110609 TV #1 Axis Interlock
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
2.3 Troubleshooting after "ERROR" Window (Error ID)
0109-001 4-20 AHI01EGP

Error ID Item Description
111001 TV #1 Axis Precheck Zeroing not completed within specified time.
111002 TV #1 Axis Precheck Pallet not drawn normally.
111003 TV #1 Axis Precheck Safty relay off.; K504
111004 TV #1 Axis Precheck Safty relay off.; K502
111005 TV #1 Axis Precheck Pallet installation error detected.; BPH504/505
111006 TV #1 Axis Precheck Rack shutter opened.; BPS502/504
111007 TV #1 Axis Precheck Pallet chuck opened.; BPS512
111008 TV #1 Axis Precheck L1 Axis Zeroing not completed
111009 TV #1 Axis Precheck
11100a TV #1 Axis Precheck
11100b TV #1 Axis Precheck Pallet detected.; BPS514
11100c TV #1 Axis Precheck
11100d TV #1 Axis Precheck
11100e TV #1 Axis Precheck
11100f TV #1 Axis Precheck Incorrect No. of Drawing Step
112001 TV #1 Axis Precheck
112002 TV #1 Axis Precheck
112003 TV #1 Axis Precheck
112004 TV #1 Axis Precheck
112005 TV #1 Axis Precheck Pallet installation error detected on operator side.;
BPH505
112006 TV #1 Axis Precheck Rack shutter closed.; BPS501/503
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.