OM-1078-002 - 第20页
2.4 Precautionary Measures before Maintenance Work 2 . 4 Precautionary Measures before Maintenance Work 031 1-003 1 8 AHI01EGP • Only qualified personnel should perform maintenance work care- fully in compliance with the…

2.3 Precautionary Items during Operation
• When the tower light (green) is "ON" or "ON and OFF" (flickering), it
shows that the static machine is in the "automatic" mode (awaiting mode).
0311-003 17
AHI01EGP
Mispicked Component
• When a pick-up error has occurred, be sure to remove the mispicked
components before starting the automatic operation.
Fig. X8
CAUTION
CAUTION

2.4 Precautionary Measures before Maintenance Work
2.4 Precautionary Measures before Maintenance Work
0311-003 18 AHI01EGP
• Only qualified personnel should perform maintenance work care-
fully in compliance
with the specified procedures.
Air Source Section
• Before performing maintenance work, turn off the power and
air sources and lock the power breaker using the padlock.
• Designate a person who can have charge of the padlock key.
• If the provided padlock is lost or damaged, purchase its sub-
stitute.
Power Supply Section
Main Valve
Padlock
(630 061 9737)
Power Breake
r
Padlock
(630 061 9737)
Fig. X9
Fig. X10
WARNING
WARNING

0311-003 19 AHI01EGP
2.5 Pre-Installation Checks
If the machine is installed in unsatisfactory environmental conditions, it
may malfunction due to damage or breakdown.
To avoid this, make preparations to install the machine as follows.
If the machine is scheduled to be transferred to another place, please
contact our marketing department or sales agency beforehand.
• Select a place solid enough to support
the weight of the machine.
Ref.: It is recommended that the ma-
chine should be installed on the
first floor. When the machine has
to be installed on a floor other
than the first one, please contact
our marketing department or
sales agency for details.
• Avoid any place that vibrates severely.
• Ambient temperature must be
20±10°C and humidity 30% to 80%.
Any dew condensation must be
avoided.
• Ensure that the selected place is free
of electric noise.
Precautionary measures (prevention of
noise generation, etc.) must be taken
for other equipment to prevent malfunc-
tions.
2.5 Pre-Installation Checks
Fig. X11
Fig. X13
Fig. X12
Fig. X14