OM-1078-002 - 第42页
1.2.3 Equipment for Operations (1) Power Breaker This multi-layer tray feeder is not provided with any power breaker . The power breaker of the main machine is commonly used for this feeder . Fig. A5 The power breaker is…

1.2.2 Safety Devices
(1) [EMERGENCY STOP] Switches
The multi-layer tray feeder is not provided with any [EMERGENCY
STOP] switches.
The [EMERGENCY STOP] switches of the main machine are com-
monly used for this feeder.
Fig. A4
The [EMERGENCY STOP] switches can be used to stop machine op-
eration in an emergency.
When one of the [EMERGENCY STOP] switches of the main machine
is pressed, the power to the feeder is turned off and the feeder stops
immediately.
When the power is turned off, the LED of the [POWER ON] button on
the operation panel illuminates in red.
• Locking the [EMERGENCY STOP] Switch
When an [EMERGENCY STOP] switch is pressed, all power is shut
off, the machine stops running, and the [EMERGENCY STOP] switch
is locked to avoid any careless power re-supply to the machine.
• Unlocking the [EMERGENCY STOP] Switch
Before re-supplying power to the machine, check and remove the
cause of emergency stop and inspect each section of the machine.
Then, unlock the [EMERGENCY STOP] switch.
To unlock the button, turn the button clockwise.
0311-003 1-5
AHI01EGP
Front Side of Machine Rear Side of Machine
[EMERGENCY STOP] Switch
[EMERGENCY STOP]
Switch
1.2 Name and Function of Each Section

1.2.3 Equipment for Operations
(1) Power Breaker
This multi-layer tray feeder is not provided with any power breaker.
The power breaker of the main machine is commonly used for this
feeder.
Fig. A5
The power breaker is provided to supply or shut off power to the ma-
chine.
The power breaker can be locked with a padlock.
Refer to "1.7.2 Locking the Power Breaker with the Padlock" in "Section
3 Outline of Automatic Operation" (the instruction manual (Vol. 1) of the
main machine) for the procedure to lock the breaker.
Before maintenance, etc., be sure to turn off the power
breaker and lock it with the padlock for safety purposes.
Table A1
Symbols/Names Functions
{ (OFF) Shut-Down Operation (Fig. A5)
tripped Power Breaker Tripped
| (ON) Power Supply
0311-003 1-6
AHi01EGP
Power Breaker
Padlock
1.2 Name and Function of Each Section
CAUTION

(2) Operation Switches
The switches for machine operations are collectively arranged.
Fig. A6 Operation Switches
*1 ELEV. POWER
This switch indicates whether or not the power to the elevator
axis is supplied.
ON: The power is supplied to the elevator axis.
*2 [HOME POSITION] Button
When this button is pressed, the elevator axis is zeroed or moved
to the replacement position (home position).
ON : This indicates that the elevator axis is located at
its origin.
ON and OFF : This indicates that the elevator axis is being ze-
roed.
OFF : This indicates that the elevator axis is not located
at its origin.
*3 [READY] Button
This button is used to tell the main machine that the tray is set
ready to be replaced with another one.
ON : This indicates that the tray is already set ready
for the replacement.
ON and OFF : This indicates that the tray is being shifted to the
replacement mode.
OFF : This indicates that the tray is set in the replace-
ment mode.
*4 [ALL CHANGE] Button
This button is used to confirm the overall tray replacement for the
empty step (the step without any components).
ON : This indicates that the overall tray replacement
can be accepted.
OFF : This indicates that the overall tray replacement
cannot be accepted.
0204-002 1-7
AHI01EGP
ALL
ALL
READY
READY
CHANGE
CHANGE
HOME
HOME
POSITION
POSITION
POWER
POWER
ELEV.
ELEV.
*1
*2
*3
*4
1.2 Name and Function of Each Section