*6 [Clear Adj.] Button When pressed, this button clears the results of the teaching opera- tion. *7 [Cancel] Button When pressed, this button cancels the results of the teaching op- eration without reflecting them on the…

100%1 / 223
5.3 "TEACHING" Window (Submenu)
5.3.1 "Traverse Ofs" Tab
Sheet Layout
When the "Traverse Ofs" tab is pressed in the "TEACHING" window
(submenu), the following tab sheet appears.
Fig. B9-1 "Traverse Ofs" Tab Sheet
Sheet Composition
*1 "Select Head" Group Box
The following button is provided in this group box.
[Tray-2] Button
*2 "Select Option (Items to be taught)" Group Box
The following buttons are provided in this group box.
[All Beam Heads Zero] Button
When this button is pressed, all X/Y beams are zeroed.
[Teach Start] Button
*4
*1
*2
*5
*3
*7
*8
*9
*6
0311-002 2-19 AHI01EGP
5.3 "TEACHING" Window (Submenu)
*6 [Clear Adj.] Button
When pressed, this button clears the results of the teaching opera-
tion.
*7 [Cancel] Button
When pressed, this button cancels the results of the teaching op-
eration without reflecting them on the offset data.
*8 [End] Button
When pressed, this button reflects the results of the teaching op-
eration on the offset data and exits from this session.
*9 "Control Switch" Group Box
Select the item (the button) to be taught and press the [ON] button
(entitled "MOVE"). After that, press the [ENABLE] button on the op-
eration panel in 2 seconds. A teaching operation is performed on
the selected item.
5.3 "TEACHING" Window (Submenu)
0204-001 2-20 AHI01EGP
5.3.2 "Pick-Up Location" Tab
Only a well-trained personnel shall perform teaching
operations.
The component library data and the pattern program
may be modified additionally for the teaching.
If the teaching operation is not performed correctly,
the pick-up rate may deteriorate.
The pick-up position of the component at the multi-layer tray feeder is
taught through manual alignment operation.
The objective feeders for teaching are those whose pick-up position
is registered in the placement feeder location data of the current pat-
tern program.
The pick-up rate may be improved after the teaching of the pick-up
position is performed when the pick-up rate is low.
Menu selections become possible only when the machine is in
the "STOP" mode.
Sheet Layout
When the "Pick-Up Location" tab is pressed in the "TEACHING" win-
dow (submenu), the following tab sheet appears inside the window.
Fig. B10 "Pick-Up Location" Tab Sheet
0311-002 2-21 AHI01EGP
5.3 "TEACHING" Window (Submenu)
*1
*2
*3
Note
CAUTION