2 Safety 2.7 Safety features User Manual SIPLACE Head Care Station 10/2017 23 2.7.2 Switches and buttons on the HCS 2.7.2.1 Position of switches and buttons on the HCS Fig.14: Control box – back side Fig.15: Head unit …

2 Safety
2.7 Safety features
22 User Manual SIPLACE Head Care Station 10/2017
Protective door and safety switch
The front protective door can be opened to exchange the placement head and connect the head to
the HCS.
The safety switch that is integrated in the head unit ensures that the door is closed and hence pre-
vents unexpected access to the inside of the head unit and interference with the connected parts
during a running verification test. In addition, it locks the door. When the door is locked, the head
verification process can be started.
To lock the door, proceed as follows:
► Install the head. (5.2.1 "Setting up the heads" [}54])
► Initialize the head. (5.2.2 "Switching on the HCS" [}61])
► Close the door.
► Press the Start button. (See item (2) in 2.7.2.1 "Position of switches and buttons on the
HCS" [}23])
If the head verification process has not started yet, you can unlock the door by pressing the Stop
button.
If the head verification process has started, you have the following options to unlock the door:
●
Click the Cancel button in the SIPLACE Test Bench software.
●
Click the Stop button at the HCS.
NOTICE
EMERGENCY OFF button
The EMERGENCY OFF button stops the power supply of 150V to the head unit, unlocks
the door and also immediately aborts all movements.
► Only press the EMERGENCY OFF button in case of an emergency.
► See item (4) in 2.7.2.1 "Position of switches and buttons on the HCS" [}23]
For more information, see 5.2.6.5 "Measurement progress" [}70].
Cover and safety switch
The cover can be removed to connect the flat ribbon cables to the board adapter corresponding to
the placement head that is currently installed on the head unit.
The integrated safety switch ensures that the power supply of 150V is stopped immediately when
the cover is opened.

2 Safety
2.7 Safety features
User Manual SIPLACE Head Care Station 10/2017 23
2.7.2 Switches and buttons on the HCS
2.7.2.1 Position of switches and buttons on the HCS
Fig.14: Control box – back side
Fig.15: Head unit - right side / top view
1 Main power switch on control box 2 EMERGENCY OFF button
3 Safety switch of door [03158868-xx] 4 Start button
5 Stop button 6 Safety switch of cover [03159513-xx]
7 HCS power switch

2 Safety
2.7 Safety features
24 User Manual SIPLACE Head Care Station 10/2017
2.7.2.2 Description of functions
Main power switch in ON position
(see item (1) in 2.7.2.1 "Position of switches and buttons on the HCS" [}23])
Switching on the main power switch provides the control box with 24VDC and 42VDC.
Main power switch in OFF position
Switching off the main power switch disconnects the complete HCS from the power supply.
DANGER
Death, serious injury or considerable damage may result if the HCS is handled incor-
rectly
► Always follow the applicable accident prevention and safety regulations (particularly
DIN EN 60204, part 1 or IEC 60204, part 1) and the safety regulations in your own
country.
HCS power switch
(see item (7) in 2.7.2.1 "Position of switches and buttons on the HCS" [}23])
Switching on the HCS power switch provides current to the head via the control box.
Switching off the HCS power switch disconnects the head from the power supply.
Start button
(see item (4) in 2.7.2.1 "Position of switches and buttons on the HCS" [}23])
The Start button performs the following tasks:
●
Initializes the head unit and the installed placement head.
●
After initializing the head, pressing the Start button again locks the door.
●
Resumes the head verification process after it was stopped.
NOTICE
Start button not active
The Start button does not work if the HCS power switch is still in the OFF position or if the
flat ribbon cables are not connected correctly.
Stop button
(see item (5) in 2.7.2.1 "Position of switches and buttons on the HCS" [}23])
The Stop button performs the following tasks:
●
Unlocks the door before a head verification process has been started
In the middle of a running head verification process, however, the Stop button neither unlocks the
door nor stops the verification process.
If a stop is required during the head verification process, you have the following options:
●
Press the EMERGENCY OFF button in case of an emergency.
●
Click the Cancel button in the software. See item (6) in 5.2.6.5 "Measurement pro-
gress" [}70].
●
Click the Stop button in the software. See item (5) in 5.2.6.5 "Measurement progress" [}70].