User Manual SIPLACE Head Care Station - - 第41页
3 HCS description 3.1 Overview of the modules User Manual SIPLACE Head Care Station 10/2017 41 3.1.6.2 Pneumatic connections for the heads Fig.30: Pneumatic connections for the heads 1 Compressed air supply [03121180-xx…

3 HCS description
3.1 Overview of the modules
32 User Manual SIPLACE Head Care Station 10/2017
Head unit – Right side view
Fig.18: Head unit – right side view
1 Door [03156199-xx] 2 Start/Stop button [00349458-xx]
3 Wheel for compressed air adjustment
[03079075-xx]
4 Filter unit [03003425-xx]
5 EMERGENCY OFF button
[03062334-xx]
6 W 201 [03009338-xx]
7 Type plate Head Care Station V2.3
[03158942-xx]
8 HCS power switch [03099566-xx]
9 Interfaces for cable connections

3 HCS description
3.1 Overview of the modules
User Manual SIPLACE Head Care Station 10/2017 41
3.1.6.2 Pneumatic connections for the heads
Fig.30: Pneumatic connections for the heads
1 Compressed air supply [03121180-xx]
with valve [03098515-xx] to all C&P20x
heads
2 Vacuum supply to all C&P20x heads
3 Exhaust line for all heads [03121180-xx] 4 Label [03092199-xx] showing which
hoses to be used for each type of head
5 Compressed air supply [03121180-xx]
with valve [03039632-xx] for the return
unit P&P module.
6 Compressed air supply [03121180-xx]
with valve [03039632-xx] for
●
PRV of all C&P20x heads
●
CPP head valve
7 Compressed air supply [03121180-xx]
with valve [03039632-xx] to PRV of
●
CPP
●
P&P module
NOTICE
Obey the label!
The label indicates which hoses are to be used for the mounted placement head.
► Obey the label(5) when mounting the heads.

3 HCS description
3.2 Technical data
42 User Manual SIPLACE Head Care Station 10/2017
3.2 Technical data
3.2.1 Placement heads supported
●
SIPLACE SpeedStar (C&P20, C&P20A+M, C&P20P+M2)
●
SIPLACE MultiStar (CPP)
●
SIPLACE TwinStar (TH)
See also
2 1.1.5 "Failure to use as prescribed" [}9]
3.2.2 Functional range
Depending on the head type, the functional range can slightly differ:
●
Condition of the vacuum system and its sub-units
●
Movement of DP- and Z-axis bearings
●
Wear on bearings / tolerances
●
Check of the component sensor
●
Check of the z-axis light barrier
●
Check of the nozzle seating
●
Position accuracy of DP drives
●
Placement force verification
3.2.3 Ambient conditions and connection values
3.2.3.1 Ambient conditions for packaging, transportation and storage
●
Temperature range between -25°C and 55°C
●
Atmospheric humidity up to 95%
●
Ambient pressure up to 1700m height without pressure equalization
3.2.3.2 Ambient conditions for machine operation
●
Room temperature between 15°C and 35°C
●
Atmospheric humidity of 30% to 75%
●
To avoid any possibility of condensation on the machine, make sure that the average atmo-
spheric humidity is no higher than 45%.
●
Ambient pressure > 750mbar (corresponds to 2500m above mean sea level)