User Manual SIPLACE Head Care Station - - 第43页

4 Setting up and commissioning 4.2 Setting up the HCS 48 User Manual SIPLACE Head Care Station 10/2017 4.2.2 Pneumatic connections ► Connect the vacuum pump or compressed air supply to the pneumatic unit as shown in the …

100%1 / 76
3 HCS description
3.2 Technical data
42 User Manual SIPLACE Head Care Station 10/2017
3.2 Technical data
3.2.1 Placement heads supported
SIPLACE SpeedStar (C&P20, C&P20A+M, C&P20P+M2)
SIPLACE MultiStar (CPP)
SIPLACE TwinStar (TH)
See also
2 1.1.5 "Failure to use as prescribed" [}9]
3.2.2 Functional range
Depending on the head type, the functional range can slightly differ:
Condition of the vacuum system and its sub-units
Movement of DP- and Z-axis bearings
Wear on bearings / tolerances
Check of the component sensor
Check of the z-axis light barrier
Check of the nozzle seating
Position accuracy of DP drives
Placement force verification
3.2.3 Ambient conditions and connection values
3.2.3.1 Ambient conditions for packaging, transportation and storage
Temperature range between -25°C and 55°C
Atmospheric humidity up to 95%
Ambient pressure up to 1700m height without pressure equalization
3.2.3.2 Ambient conditions for machine operation
Room temperature between 15°C and 35°C
Atmospheric humidity of 30% to 75%
To avoid any possibility of condensation on the machine, make sure that the average atmo-
spheric humidity is no higher than 45%.
Ambient pressure > 750mbar (corresponds to 2500m above mean sea level)
4 Setting up and commissioning
4.2 Setting up the HCS
48 User Manual SIPLACE Head Care Station 10/2017
4.2.2 Pneumatic connections
Connect the vacuum pump or compressed air supply to the pneumatic unit as shown in the
following picture:
Fig.34: Pneumatic unit
1 Spiral coiled tube for vacuum pump con-
nection
2 Main valve for compressed air supply
3 1/2" tube for compressed air generator
connection
NOTICE
Input valves not closed
Ensure the input valves are closed when connecting either the compressed air supply or the va-
cuum pump.
4.2.3 Adjusting the pneumatic supply
Fig.35: Adjustment wheel and manometer
 CAUTION!
Risk of injury due to loose pneumatic hoses!
Always ensure that the valves of the pneu-
matic connections for the heads are closed
before opening the main valve for com-
pressed air.
.
Ensure that all valves of the pneumatic connec-
tions for the heads are closed.
Open the main valve of the compressed air sup-
ply.
Pull off the cap(1) of the adjustment wheel.
Turn the adjustment wheel until the mano-
meter(2) shows 4.8 bar.
Push down the cap(1) of the adjustment wheel to
secure the setting.
Close the main valve of the compressed air sup-
ply.
4 Setting up and commissioning
4.3 Software HCS
52 User Manual SIPLACE Head Care Station 10/2017